Forced Operation - Fujitsu AMUG24LMAS Service Manual

Duct type
Hide thumbs Also See for AMUG24LMAS:
Table of Contents

Advertisement

10. FORCED OPERATION

FORCED AUTO OPERATION
If a wireless remote control or battery power is lost,
this function can work without a remote control.
This function starts by pushing a body button for 3 seconds
like the below table.
(It doesn't work when a body button is pushed for 10 seconds.)
Forced auto operation
Operation mode
Set temperature
Fan control mode
Louver (group)
Louver (individual)
Timer mode
Economy
Energy saving fan
Swing
Human sensor
FORCED COOLING OPERATION
This function is for cooling test operation and pump down.
This function starts by pushing a body button for 10 seconds
like the below table.
Forced cooling operation
Operation mode
Set temperature
Fan control mode
Set louver direction
Louver swing
Louver (individual)
Timer mode
Economy
Energy saving fan
Left and right swing
Human sensor
Auto changeover
75°F (24°C)
Auto
Last position
Off
Continuous operation
Off
As a setting
Off
Off
Cooling
75°F (24°C)
High
Standard position
Off
Released
Continuous operation
Off
As a setting
Off
Off
04-24