Fujitsu AMUG24LMAS Service Manual page 160

Duct type
Hide thumbs Also See for AMUG24LMAS:
Table of Contents

Advertisement

¢ Description of display
LED display lamp
(1) POWER/MODE
(2) ERROR
(3) MONITOR
Switch
SW1
Push
SET1-1
DIP
For selecting cooling or heating during test operation.
SET1-2
DIP
For switching SW1 operation.
SET1-3
DIP
(Prohibited)
SET1-4
DIP
(Prohibited)
SET2-1
DIP
SET2-2
DIP
(Prohibited)
SET2-3
DIP
(Prohibited)
SET2-4
DIP
(Prohibited)
SET3-1
DIP
(Prohibited)
SET3-2
DIP
(Prohibited)
SET3-3
DIP
(Prohibited)
SET3-4
DIP
(Prohibited)
Be sure to disconnect the power supply or turn off the breaker before changing the DIP switch
setting.
2-1. Setting methods
Green
Red
A
Red
B
Red
C
Red
D
Red
E
Red
F
Red
Function or operation method
For the test run start and stop.
For the pump down start and stop.
For selecting outdoor unit low noise operation function.
To use this function, the Central remote controller
(option) is necessary.
- (05-12) -
Function or operation method
Turns on when the power supply is ON (Including
when error occurs).
Indicate the MODE by the number of flashes when
the installation function is active.
Flashes at high-speed when there is an error.
Displays the location and contents of errors when
there is an error. (Refer to
code"
on page 05-16 for details.)
Chapter 3-2. "Error
Factory setting
OFF
OFF
OFF (Do not change)
OFF (Do not change)
OFF
OFF (Do not change)
OFF (Do not change)
OFF (Do not change)
OFF (Do not change)
OFF (Do not change)
OFF (Do not change)
OFF (Do not change)
2. Function settings (For outdoor unit)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents