Resetting Error Codes In Hard Lockout Condition - Bradford White EF100T150(E)*(N Service Manual

Ultra high efficiency water heaters
Table of Contents

Advertisement

Resetting Error Codes
For models with Honeywell Integrated Control
WARNING
The following procedure is for service and installation personnel only. Resetting lockout
conditions without correcting the malfunction can result in a hazardous condition.
If an error code is displayed (except for #4, low flame sense current), the water heater will be in a "lockout condition"
with the water heater display showing the error code number and "Service Needed" in the status section of the
display window. Error codes 62 (maximum number of retries detected) and 63 (maximum number if ignition
recycles detected) are "Soft Lockouts" in which the control can be reset in the "User Mode" by pressing the lower
right button under "Lockout Reset" shown in the lower right portion of the display. The control will also go through 3
attempts to relight the burners every hour in the soft lockout condition.
Error Code Shown in
Water Heater Display
Status
Service needed
%
SELECT
Lockout RESET
Press for 2 seconds
All other error codes will put the water heater into a "Hard Lockout" condition, in which the water heater will not
operate and cannot be reset in the "User Mode". To reset a hard lockout, first enter the "Service Mode" described
earlier by pressing both the "Temperature Up" and "Select Buttons" at the same time for 3 seconds. Then press the
lower right button under "Lockout Reset" in the water heater display and hold for 3 seconds.

Resetting Error Codes in Hard Lockout Condition

Error Code Shown in
Water Heater Display
%
Status Service Needed
Status Service Needed
&
SELECT
SET
SELECT
Lockout RESET
Step 2: Press for 3 seconds to
Step 1: Press for 3 seconds
reset control in service mode.
to enter service mode.
34
34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save Article as PDF