ADF Web HD67B31 Series User Manual

Opc ua server / bacnet master - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
OPC UA Server / BACnet Master -
Converter
(Order Code: HD67B31-B2)
for Website information:
http://www.adfweb.com/?Product=HD67B31
for Price information:
http://www.adfweb.com/?Price=HD67B31-B2
Benefits and Main Features:
Triple electrical isolation
Power Supply 18...35V DC and 8...24 V AC
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual OPC UA Server / BACnet Master
Document code: MN67B31_ENG
Revision 1.000
For others OPC UA Server devices, see also the following links:
OPC UA Server from/to ...
www.adfweb.com?Product=HD67B26
www.adfweb.com?Product=HD67B27
www.adfweb.com?Product=HD67B28
www.adfweb.com?Product=HD67B29
www.adfweb.com?Product=HD67B30
www.adfweb.com?Product=HD67B32
www.adfweb.com?Product=HD67B33
www.adfweb.com?Product=HD67B34
www.adfweb.com?Product=HD67B35
www.adfweb.com?Product=HD67B36
www.adfweb.com?Product=HD67B37
www.adfweb.com?Product=HD67B38
www.adfweb.com?Product=HD67B39
www.adfweb.com?Product=HD67B40
www.adfweb.com?Product=HD67B41
www.adfweb.com?Product=HD67B42
www.adfweb.com?Product=HD67B43
www.adfweb.com?Product=HD67B44
www.adfweb.com?Product=HD67B45
www.adfweb.com?Product=HD67B46
www.adfweb.com?Product=HD67B47
www.adfweb.com?Product=HD67B48
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Page 1 of 30
(Serial)
(Modbus Master)
(Modbus Slave)
(Modbus TCP Master)
(Modbus TCP Slave)
(Bacnet Slave)
(CAN)
(CANopen)
(DeviceNet Master)
(DeviceNet Slave)
(DMX)
(EtherNet/IP Master)
(EtherNet/IP Slave)
(J1939)
(KNX)
(MQTT)
(NMEA0183)
(NMEA2000)
(PROFINET Master)
(PROFINET Slave)
(SNMP Manager)
(SNMP Agent)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67B31 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67B31 Series

  • Page 1 User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 1 of 30 Industrial Electronic Devices User Manual Revision 1.000 English OPC UA Server / BACnet Master - Converter (Order Code: HD67B31-B2) For others OPC UA Server devices, see also the following links: for Website information: OPC UA Server from/to …...
  • Page 2: Table Of Contents

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 2 of 30 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 3 of 30 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 4 of 30 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 5 of 30 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67B31-IP-B2 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 6 of 30 Industrial Electronic Devices Figure 1b: Connection scheme for HD67B31-MSTP-B2 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 7: Characteristics

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 7 of 30 Industrial Electronic Devices CHARACTERISTICS: The HD67B31-B2 is a OPC UA Server / BACnet Master converter. It allows the following characteristics: Up to 1500 bytes in reading and 1500 bytes in writing; Two-directional information between BACnet and OPC UA;...
  • Page 8: Power Supply

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 8 of 30 Industrial Electronic Devices POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin...
  • Page 9: Function Modes

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 9 of 30 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’: The first, with Dip1 in Off position (factory setting), is used for the normal working of the device. The second, with Dip1 in On position, is used for upload the Project/Firmware.
  • Page 10: Leds

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 10 of 30 Industrial Electronic Devices LEDS: The device has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 11: Rs485 (For Bacnet Ms/Tp)

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 11 of 30 Industrial Electronic Devices RS485 (for BACnet MS/TP): For terminating the RS485 line with a 120Ω resistor it is necessary to put ON dip 1, like in figure. The maximum length of the cable should be 1200m (4000 feet).
  • Page 12: Ethernet

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 12 of 30 Industrial Electronic Devices ETHERNET: The Ethernet connection must be made using Connector3 of HD67B31-xxx-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 13: Use Of Compositor Sw67B31

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 13 of 30 Industrial Electronic Devices USE OF COMPOSITOR SW67B31: To configure the Converter, use the available software that runs with Windows called SW67B31. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 14: New Project / Open Project

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 14 of 30 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “OPC UA Server / BACnet Master Converter”...
  • Page 15: Software Options

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 15 of 30 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor. In the section “Language”...
  • Page 16 User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 16 of 30 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 17: Set Communication

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 17 of 30 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, OPC UA Server and BACnet Master. By Pressing the “Set Communication”...
  • Page 18 User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 18 of 30 Industrial Electronic Devices OPC UA S ERVER The means of the fields for “OPC UA Server” are: In the field “IP Address” the IP address for OPC UA side of the converter is defined;...
  • Page 19 User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 19 of 30 Industrial Electronic Devices MS/TP): ASTER This section is used to define the main parameters of BACnet MS/TP line. The means of the fields are: In the field “Baudrate”...
  • Page 20: Opc Ua Access

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 20 of 30 Industrial Electronic Devices OPC UA ACCESS: By Pressing the “OPC UA Access” button from the main window for SW67B31 (Fig. 2) the window “OPC UA Server Access” appears (Fig. 4). This section is used to define the list of OPC UA variables to read/write.
  • Page 21: Set Bacnet Access

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 21 of 30 Industrial Electronic Devices SET BACNET ACCESS: By Pressing the “Set BACnet Access ” button from the main window of SW67B31 (Fig. 2), the window “Set BACnet Access” appears (Fig. 5).
  • Page 22 User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 22 of 30 Industrial Electronic Devices In the field “D Add” the address of the endpoint is defined. If “D Len” is ‘1’ it is possible to insert a number from 1 to 255; if “D Len” is ‘2’...
  • Page 23 User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 23 of 30 Industrial Electronic Devices Figure 5b: “Set BACnet Access  BACnet Write” window The means of the fields in the window (Write) are the following: In the field “IP Address / ID”...
  • Page 24 User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 24 of 30 Industrial Electronic Devices In the field “Max Error” the number of consecutive errors that the Master waits before stopping the specific requests is defined; In the field “Position”...
  • Page 25: Update Device

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 25 of 30 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 26 User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 26 of 30 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67B31 device. Warning: If Fig.
  • Page 27: Mechanical Dimensions

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 27 of 30 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 8: Mechanical dimensions scheme for HD67B31-xxx-B2 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 28: Ordering Informations

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 28 of 30 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD67B31 – xxx - B 2 Connectors Type 2: Fixed Screw Terminal Enclosure Type...
  • Page 29: Disclaimer

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 29 of 30 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 30: Warranties And Technical Support

    User Manual OPC UA Server / BACnet Master Document code: MN67B31_ENG Revision 1.000 Page 30 of 30 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

This manual is also suitable for:

Hd67b31-b2Hd67b31-ip-b2Hd67b31-mstp-b2

Table of Contents