Cooling Data And Noise; Terminal And Cable Entry Data For The Input Power Cable - ABB ACS880-307LC Hardware Manual

Diode supply units
Table of Contents

Advertisement

Cooling data and noise

Supply unit type
ACS880-307LC-...
U
= 690 V
N
6-pulse
0490A-7+A018
0780A-7+A018
1060A-7+A018
1470A-7+A018
2000A-7+A018
3000A-7+A018
4000A-7+A018
5000A-7+A018
6000A-7+A018
12-pulse
0920A-7+A004+A018
1470A-7+A004+A018
2000A-7+A004+A018
2940A-7+A004+A018
4000A-7+A004+A018
6000A-7+A004+A018

Terminal and cable entry data for the input power cable

These drawings (from front, side and above) show the terminal and cable entry dimensions
for incoming cubicles. The dimensions are given in millimeters. Tightening torque for the
cable lug connection depends on the bolt size and type. See section
torques (page
98).
Coolant volume
Modules
Modules +
cabinet
l
l
0.6
3.5
0.6
3.5
0.6
3.5
1.2
4.2
1.2
4.2
1.8
7.7
2.4
8.4
3.0
11.9
3.6
12.6
1.2
4.2
1.2
4.2
1.2
4.2
2.4
8.4
2.4
8.4
3.6
12.6
Coolant flow rate
Modules
Modules +
cabinet
l/min
l/min
14
20
14
20
14
20
28
34
28
34
42
54
56
68
70
88
84
102
28
34
28
34
28
34
56
68
56
68
84
102
Tightening
Technical data 95
Noise level
Pressure
Average
loss
kPa
dB (A)
120
65
120
65
120
65
120
65
120
65
120
67
120
67
120
68
120
68
120
67
120
67
120
67
120
68
120
68
120
68

Advertisement