Functional Safety HiD2022*, KFD2-STC5-(Ex)*, KFD2-STV5-(Ex)*
Operation
Signal calibration
Zone 0, 1, 2
Div. 1, 2
Figure 5.2
Usage in Zone 0, 1, 2/Div. 1, 2 only for KFD2-STV5-Ex1-1, KFD2-STV5-Ex1-2,
KFD2-STV5-Ex2-1, and KFD2-STV5-Ex2-2
The KFD2-STV5-1-1, KFD2-STV5-Ex1-1, and KFD2-STV5-Ex1-2 devices have
no second channel.
4 mA ... 20 mA
1
2
3
4
5
6
Proof test set-up for KFD2-STV5-(Ex)*-1 and KFD2-STV5-(Ex)*-2
KFD2-STV5-Ex2-2
7-
500 Ω
8+
9
250 Ω
10-
500 Ω
11+
12
250 Ω
14+
15-
Multimeter
(mA)
Multimeter
(mA)
I
supply
24 V DC
Power
Zone 2
supply
Div. 2
23
Need help?