Download Print this page

Q-tran QOM-eLED+IA Quick Start Manual page 6

Led power supply 60w-200w

Advertisement

INSTALLATION
DMX512 signal input
MENU Select
Menu
>1 set mode
2 IC config
3 LED type
Enter
1 set mode
Menu
>1:DMX mode
2:RF mode
Enter
2 IC config
Menu
>1:TM1812
2:WS2801
3:WS2812
Enter
3 LED type
Menu
>1:RGB
2:RBG
3:GRB
Enter
4 DMX address
Menu
start: 000
end:
Enter
5 Output length
Menu
Enter
© 2020 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com
OLED panel
Menu
Enter
GND
D+
P
RI:
Uin=5-24VDC
Iin=0.2A Max
D-
SEC:
Uout=SPI Signal
TEMP RANGE:-20℃-+50℃
GND
D+
D-
DMX512 signal output
There are four buttons for configuration of settings with the OLED display:
Up
"Menu," "Enter," "Up" and "Down," Click "Menu" button to enter the menu
selection interface, and keep clicking "Up" and "Down" buttons you will get
5 settings one by one as follows:
Down
1. Set mode: to select an operation mode, click "Enter" button to enter the
Up
configuration interface, then click "Up" or "Down" buttons to choose DMX mode,
click "Menu" button to confirm the setting and return to menu selection interface.
This setting should be in DMX mode for use with a DMX controller.
Down
2. IC config: to set driving IC type, click "Enter" button to enter the configuration
Up
interface, click "Up" and "Down" buttons to choose an IC type that drives your LED
lights, click the "Menu" button to confirm and return to menu selection interface. Total 34
kinds of driving IC available. This should be set to WS2811L for all Q-Tran IA
e
Down
Products
3. LED type: to set RGB/RGBW color order, click the "Enter" button to enter the configura-
Up
tion interface, click "Up" and "Down" buttons to choose a color order, click the "Menu" button
to confirm and return to menu selection interface. Total 7 kinds of color order available. The
LED type should be RGB for SWIA, and RGB IA, while it should be RGBW for RGBW
Down
IA or RGBA IA
4. DMX address: to set DMX address under DMX mode, click the "Enter" button to enter the
Up
configuration interface, the cursor will be on the "hundreds" position of the start address, click
the "Up" and "Down" buttons to change the number, click the "Enter" button to confirm and
0600
move the cursor to "tens" position and set, then "units" position, and then the end address,
Down
and click the "Menu" button to confirm the setting and return to menu selection interface.
Should be set based on the number of addresses needed. 000 to 511 would allow
maximum length.
5. Output length: to configure total output channels, click the "Enter" button to enter the
Up
configuration interface, the asterisk is on the "thousands" position, click the "Up" and "Down"
**
buttons to change the number, click the "Enter" button to confirm and move the asterisk to
3060
"hundreds" position and set, then "tens" position and "units" position, and click the "Menu"
Down
button to confirm and return to menu selection interface. The SPI controller supports max.
3060 output channels. This should be set to 3060 to max to allow for longest control.
LED POWER SUPPLY - QOM-eLED+IA
● Please check the operation voltage of
LED strip and confirm the input voltage
● Do not change while powered
● All Q-TRAN products are 12V or 24V
12-24V
Up
5V
Down
CLK
DATA
Learning button
DC power input
DC power output
Connect with digital
IC LED lights
DO NOT USE CLK
Specification subject to change. Rev-09-29-20