Digitalmultimeter true rms
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
Resistance measurement
Attention!
Before making any measurements, make sure the circuit is disconnected from
any power source and all capacitors are properly discharged!
1. Set the rotary switch to the position
Attach the pin-plug of the black test lead to the COM-jack and the
2.
pin-plug of the red test lead to the V Ω Hz-jack.
Connect the black test prod to the negative pole and the red test
3.
prod to the positive pole of the circuit to be tested.
Once the reading stabilizes, read the value. If the polarity is twisted a
4.
"Minus sign" is displayed. Use the HOLD function if the reading is
difficult to read.
Continuity test
Attention!
Before making any measurements, make sure the circuit is disconnected from
any power source and all capacitors are properly discharged!
1.
Set the rotary switch to the position
2.
Attach the pin-plug of the black test lead to the COM-jack and the
pin-plug of the red test lead to the V Ω Hz-jack.
3.
Connect the black test prod to the negative pole and the red test prod
to the positive pole of the circuit to be tested.
4.
If the resistance is less than about 30 Ω, you hear an audible signal. If
the circuit is open, the display shows "OL".
Diode testing
1. Set the rotary switch to the position
2. Touch the diode to be tested with the probes. The forward voltage shows
400 to 700mV. The counter voltage shows „OL". Defective devices show a
value about 0 mV or „OL" in both polarities.