DoorKing 1838 Installation & Owner's Manual page 3

Pc programmable multi-door access controller
Table of Contents

Advertisement

Overview for 1838 Keypad Programming
Section 3.2 Setup 1838 for PC Programming
Master Code REQUIRED
Resident Elevator Button Relay Time
Tone Open Sound ON or OFF
RS-232 Speed Setting
Switch Input Feature
Elevator Control Feature
Single or Multiple 1838s using ONE Phone Line
DKS Data over IP OR DKS Cellular Assigned Phone Number or ID Number
Re-Program Memory Size, with/without Cards and Anti-Pass Back
(Only needed when New 1838 system is used with OLDER 1838 systems)
Live Transactions Viewing on a PC - ON or OFF
Display DKS Data over IP Phone Number or System ID Number
Test Connection to DKS Data over IP
Turn DKS Data over IP OFF or ON (Automatically ON after programming 3.2.10)
Section 3.3 General Programming using 1838 Keypad
Relay Strike Time
Talk Time
Tone Open Numbers
Switch Input Relay(s) Activation
Touch-tone / Rotary-dial
Rotary Dial-9 Relay(s) Activation
Section 3.4 Not Applicable to 1838
Section 3.5 Programming Phone Numbers
Programming the Directory Code Length
Programming Directory Code AND 7-Digit Phone Numbers - No Area Code
Programming Area Codes
Programming Phone Numbers that need Area Codes
Deleting Individual Phone Numbers
Delete Area Codes
PBX Line Access Code Programming
Touch-Tone Dialing Pause
Section 3.6 Programming 5-Digit PIN Device Codes
Programming Five-Digit PIN Device Codes
Delete Device Codes
Enabling Facility Codes
Programming Facility Codes
Section 3.7 Programming Four-Digit Entry Codes
Programming Four-Digit Entry Codes
Delete Entry Codes
Entry Code Ranges
Section 3.8 Anti-Pass Back
Programming the Anti-Pass Back Mode
Re-Sync All Devices
Re-Sync Individual Devices
Reset Facility Counter
Note: Program section numbers have been intentionally skipped that DO NOT apply to the specific access controller in this manual. This allows ALL of the
1830 series manuals (1834-065 rev H or higher and 1835-065) to remain in sync with each other when referencing programming numbers.
1838-065 Issued 3-19
Version D
Page #
Section Command
Master
25
3.2.1
Switch ON
26
3.2.4
* 36
26
3.2.5
* 15
26
3.2.6
* 85
26
3.2.7
* 18
27
3.2.8
* 75
27
3.2.9
* 04
27
3.2.10
* 59
28
3.2.11
* 95
28
3.2.12
* 19
47
6.1.7
* 56
47
6.1.8
* 29
47
6.1.9
* 55
30
3.3.1
* 03
30
3.3.2
* 08
31
3.3.3
* 05
31
3.3.4
* 50
32
3.3.5
* 07
32
3.3.6
* 51
33
3.5.1
* 20
33
3.5.2
* 01
34
3.5.3
* 24
34
3.5.4
* 41
35
3.5.6
* 01
35
3.5.8
* 24
35
3.5.10
* 09
35
3.5.11
* 27
36
3.6.1
* 70
36
3.6.2
* 71
36
3.6.3
* 72
36
3.6.4
* 73
37
3.7.1
* 02
37
3.7.2
* 02
37
3.7.3
* 12
38
3.8.1
* 43
38
3.8.2
* 45
38
3.8.3
* 46
38
3.8.4
* 48
Factory Setting
No factory setting
007 (7 sec)
1 (tone ON)
1 (19200 Baud)
0 (activates relay)
1 (Turned ON)
Single 1838
Issued by DoorKing
8-3000 Memory
2-Card w/Anti-Pass Back
OFF
Testing Option
Testing Option
Testing Option OFF
Relay 0: 01 (1 sec)
Relay 1: 01 (1 sec)
Relay 2: 01 (1 sec)
060 (60 sec)
Relay 0: # # # #
Relay 1: 9 8 7 6
Relay 2: 5 4 3 2
010 (relay 1 activates)
Touch-tone
010 (relay 1 activates)
Three (3) digits
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
1 (Pause ON)
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
Quick Guide - 2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents