2.3.3 Tracker Expansion Boards using 900 MHz Wireless Communication
The model 2358 Tracker Expansion Board (sold separately) allows you to expand the number of remote entry points that the
access controller can control. One tracker expansion board is required for EACH remote entry point. Communicate wirelessly
between the tracker expansion boards and the 1838 controller without having to run wiring from each remote access point to
the 1838 controller. The model 1470 wireless tracker expansion board kit and the model 2333 wireless baseboard kit (each sold
separately) plugged onto to circuit boards for wireless communication. Wireless tracker expansion boards can be up to 100 ft
from the access controller (approximate). This distance can be extended by using longer range antennas (sold separately)
and/or a 2332 wireless dual band repeater (sold separately). Each tracker expansion board must have a board address set on it
to identify it to the access controller. Board addresses 3-10 will activate RELAY 2 and 11-18 will activate RELAY 1 on the
access controller. Board addresses can be set the same for multiple boards (zone addresses) when MORE than 8 boards need
to activate a specific RELAY (24 boards MAX for each relay). The tracker expansion boards are pre-programmed with many
features but can be programmed for specific needs when desired (See Tracker Expansion Board Manual 2358-065 for ALL
programming options). See DoorKing's web site and the instruction sheets with the wireless kits for complete installation
information when using wireless communication.
This access control equipment must be installed inside of a controlled, protected or restricted area. See page 3 for more information.
Access Controller
Circuit Board
NET ID
CH
4
4
4
RESET
DENY
ACT
RF
GRANT
STRENGTH
2333 Wireless
2333 Wireless
CODE RCVD
2333 Wireless
HEARTBEAT
RXD
STATUS
900 MHZ
900 MHZ
900 MHz
Baseboard Kit
Baseboard Kit
TXD
Baseboard Kit
Digital Screen
ON
Relay 2 Jumper
MASTER
CODE
OFF
Set to NO
KEYPAD
Relay 0
NO
NC
NO NC
C
Main Terminal
R
IMD
5VDC
IMC
Z
A
2C
2RY
1C
1NC
Relay 2
Relay 1
Relay 0
Main
Door/Gate
Relay 2 Connection Required.
Type of wiring to be used on ALL external devices:
A) Type CL2, CL2P, CL2R, or CL2X.
B) Other cable with equivalent or better electrical,
mechanical, and flammability ratings.
16
Antenna
Required
ELEVATOR
1
2
3
Power
DOORKING
Transformer
2363-010
Required.
Connect to
14
13
#1 and #2.
12
11
6
5
4
3
GND
2
1
Auxiliary Terminal
4-Pin Terminal
Connection
2333-010
2333 010
ENTER
Digital Screen Note: 2333 board is
mounted in cabinet sideways and digital
numbers are read top to bottom.
1NO
BAT
16AC
16AC
Cabinet Mounted
900 MHz Antenna Kit
P/N 1514-019
Range is Up to 1000 ft
direct-line-of-sight.
200 ft max
Antenna Note: This wireless
system works best when the
antennas are in direct-line-
of-sight with each other, in
free air as high as possible
above the ground
1
2
3
Wiegand Card
4
Reader
5
6
#6 - #9
7
Connect card
8
reader using
9
10
4 conductor,
11
stranded with
12
overall shield.
13
18, 20, 22 or
14
24 gauge.
15
16
17
18
19
20
2358-010 Tracker
Expansion Board
At a Remote Entry Point
Read as "E2".
Antenna Options
Externally Mounted
900 MHz Antenna Kit
P/N 1514-079
Range is Up to 1000 ft
direct-line-of-sight.
13 ft
of cable out of
bottom of cabinet
Antenna
Required
Signal Note: Channel Number
and RF ID Number must match
on 2333 wireless baseboard kit
and ALL 1470 wireless kits.
NET ID
4
4
Lock Power
Board
UL listed
Address
Setting
RF
OUTPUT
ALARM
AUX
2358-010
SECURE
RF
RF
CODE
CODE
CODE
RELAY
RELAY
RELAY
BOARD ADDRESS
DATA
STATUS
SENT
GOOD
BAD
NC
NC
NC
ON
NO
NO
NO
1
0
1470-010
1470
1470
1470
RXD
SX1276
900 MHz
900 MHz
TXD
900 MHz
RF
STRENGTH
Wireless
Wireless
Wireless
POWER
NET ID
CH
Kit
Kit
Kit
PROGRAM
4
4
4
RESET
ENT
Board Power
IMPORTANT NOTE: ONLY use circuit
board 2358-010 Rev N or higher.
900 MHz
Range is Up to 200 ft
Disc Antenna
direct-line-of-sight.
(Supplied)
900 MHZ Wireless
Dual Band Repeater
P/N 2332-080
Range is Up to 1000 ft
direct-line-of-sight.
CH
4
Door Lock
#25 & #26
or Gate
21
Operator
22
23
24
25
26
27
28
29
30
31
Ground #32
32
33
34
16 VAC
20 VA
UL listed
#33 & #34
1838-065 Issued 3-19
Version D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents