3.6
Aligning the drain body horizontally
3.7
Installation in the concrete slab (black tub)
Clamp the on-site sealing sheet <68> between the pressure sealing flange
<13> and the counterflange <47> and screw together using the
screws <48>.
Note: If there is no on-site sealing sheet available, the
Kessel sealing gasket set 83023 incl. elastomer
waterproofing sheet must be used.
010-843
Installation
34 / 132
Fig. [12]
Fig. [13]
2017/04
48
47
68