Bauer Compressors P0 Instruction Manual And Replacement Parts List page 94

Breathing air purification systems and industrial air purification systems
Table of Contents

Advertisement

• Allow the compressor to cool before servicing. Whenever the compressor is shut down and over-
heating is suspected, a minimum period of 15 minutes must elapse before opening the crankcase.
Premature opening of the crankcase of an overheated unit can result in an explosion.
• Incorrect placement of the inlet and pressure valves in a compressor cylinder head can cause an
extremely dangerous condition. Refer to the appropriate section of this manual before installing or
replacing valves.
• Before doing any work involving maintenance or adjustment, be sure the electrical supply has been
disconnected, and the complete compressor system has been vented of all internal pressure. Failure to
follow these warnings may result in an accident causing personal injury and/or property damage.
• Before working on the electrical system, be sure to disconnect the electrical supply from the system at
the circuit breaker or other manual disconnect. Do not rely on the ON/OFF switch to disconnect the
electrical supply.
• Installer must provide an earth ground and maintain proper clearance for all electrical components.
• All electrical installation must be in accordance with recognized national, state, and local electrical
codes.
• Do not use gasoline, diesel fuel or other flammable products as a cleaning solution.
• A compressor which has been used for gas service is unsuitable for air applications. Should the
purchaser and/or user proceed to use the compressor for air service after it has been used for gas, the
purchaser/user assumes all liability resulting therefrom without any responsibility being assumed by
Bauer Compressors, Inc. The purchaser is urged to include the above provision in any agreement for
resale of this compressor.
• The use of repair parts other than those listed in this manual or purchased from BAUER Compressors,
Inc. may create unsafe conditions over which BAUER has no control. Such unsafe conditions can
lead to accidents that may be life-threatening, cause substantial bodily injury, and/or result in damage
to the equipment. Therefore, BAUER Compressors, Inc. can bear no responsibility for equipment in
which non-approved repair parts are installed
Page 87
Purification Systems
3rd Edition, Rev 0 Chg 6

Hide quick links: