MNL-0096

5.2.2.2 Chamber

To change the cartridge, proceed as follows. See Figure 5-3 Disconnect the power and shut off the inlet
supply line, if applicable.
1. Depressurize the system by means of the bleed valve.
2. Unscrew the filter head using the Seccant Filter Key (P/N# 066690 or N29373).
3. Screw the supplied T-wrench (extraction key P/N# 067146) onto the threaded rod in the top of the
cartridge. Pull out the cartridge with the T-wrench.
4. Dispose of the dirty cartridge in accordance with local, state, and federal regulations.
5. Dry the inside of the chamber with a clean cloth and check for corrosion.
6. Replace all corroded parts with new BAUER parts.
7. Remove the shipping covering from the new cartridge and remove the protective cap from the bot-
tom of the cartridge.
8. Lubricate the O-rings with white petroleum jelly. Apply sparingly.
9. Firmly install the new cartridge. Be sure the cartridge snaps into place.
10. Reinstall the filter head.
April 17, 2013
Figure 5-2
Oil and Water Separator
1
2
3
1. Filter Head
2. Sintered Metal Filter
4
3. Acorn Nut
4. Hex Nuts
Page 62