CHAPTER 4: MULTI-CHAMBER PURIFICATION SYSTEMS

4.1 Applicability

This chapter applies to these Bauer Purification System models: P1, P2, P2S, IP2S, P4, P5, P5S, IP5S,
P10, P10S, IP10S, P41,P41S, IP41, IP41S, P42, P42S, IP42, IP42S, P43, P43S, IP43 and IP43S.

4.2 Components Layout

The minimum components of all Bauer Air Purification Systems are a Oil and Water Separator and a
Purification Chamber. Different models add one or more Dryer Chambers and replace the Purification
Chamber with a Securus
nents generally include a Condensate Drain Valve, Check Valves, a Bleed Valve, a Pressure Maintaining
Valve, and a Safety Valve. Figure 4-1 shows the typical interconnection of these components.
Figure 4-1
8
IN
1
2
1. Oil and Water Separator
2. Condensate Drain Valve
3. Check Valves
4. Dryer Chamber
Page 23
Electronic Moisture Monitor System Purification Chamber. Additional compo-
®
Typical Bauer Purification System
4
3
5
7
3
6
5. Purification Chamber
6. Bleed Valve
7. Pressure Maintaining Valve
8. Safety Valve
Purification Systems
OUT
3rd Edition, Rev 0 Chg 6