11. Close the bleed valve, restore the power and reconnect the inlet supply line, if applicable.
If air is detected bleeding out from the bottom of the chamber, the cartridge has not been installed
properly or is missing. Follow the instructions in Paragraph 5.2.2.3.
5.2.2.3 Cartridge Leaks after Installation
1. Remove the cartridge following steps to 3.3. in Paragraph 5.2.2.2.
2. Install cartridge if it is missing.
3. Remove cartridge with the T-wrench and inspect O-rings.
4. Replace O-rings if necessary.
5. Ensure protective caps and devices have all been removed.
6. Replace cartridge following steps 8. 7. to 11.11. in Paragraph 5.2.2.2.
Page 63
Figure 5-3
Cartridge Replacement
Thread
On
NOTICE
Purification Systems
Pull
Out
3rd Edition, Rev 0 Chg 6