Operation - Omron E3S-C Manual

General--purpose photoelectric sensor
Hide thumbs Also See for E3S-C:
Table of Contents

Advertisement

E3S-C

Operation

FUZZY LOGIC MUTUAL INTERFERENCE PREVENTION FUNCTION

(FOR E3S-CR
AND E3S-CD
If photoelectric sensors are installed side by side, each Sensor may
be influenced (or malfunction) by the light emitted from the other
sensors. This is known as mutual interference.
The fuzzy logic mutual interference prevention function of the
E3S-C enables the E3S-C to monitor light interference over a cer-
tain period of time. Before the E3S-C starts emitting light, the E3S-C
retrieves the intensity and frequency of surrounding light interfer-
ence as data. Using this data, the E3S-C calculates, with fuzzy infer-
ence, the risk of the E3S-C malfunctioning and controls the timing of
the E3S-C's light emission.
SENSITIVITY ADJUSTMENT (REFLECTIVE SENSORS)
Steps
Step 1
Function
Determine position A
Sensing
Photoelectric sensor
condition
Sensitivity
A
adjustor
Min.
Indicators
OFF
STABILITY
(green)
Procedure
Place target at the desired sensing
distance. Set sensitivity adjuster to the
minimum scale position, and gradually
increase sensitivity by turning the
sensitivity adjuster clockwise until the
Light Incident indicator (red LED)
turns ON. Position A designates the
point at which the LED has turned on.
Unlike conventional photoelectric sensors, the variation in the sensitivity among several E3S-C photoelectric sensors is minimal. This
means the sensitivity can be adjusted on only a single photoelectric sensor, and then the adjusters on the other E3S-C photoelectric sen-
sors can be set to the same scale position. There should be no need to adjust the sensitivity of each photoelectric sensor individually.

ONLY)
Step 2
Determine position B
Photoelectric sensor
Max.
Min.
ON
OFF
LIGHT
STABILITY
(red)
(green)
Remove the target. Starting from the
maximum scale position, gradually
decrease sensitivity by turning the
sensitivity adjuster counterclockwise
until the Light Incident indicator (red
LED) turns OFF. Position B
designates the point at which the LED
has turned OFF.
When the risk is low, the E3S-C waits until there is no light interfer-
ence and emits light.
Light interference
Emission pattern
When the risk is high, the E3S-C emits light between each light inter-
ference moment.
Light interference
Emission pattern
Step 3
Adjust to optimum setting
B
Max.
OFF
OFF
LIGHT
(red)
Set the sensitivity indicator to the
position between Positions A and B (in
some cases, Positions A and B are
opposite of the above example). The
photoelectric sensor will then work
normally if the stability indicator
(green) is lit with and without the
target. If it is not lit, stable operation
cannot be guaranteed,in which case a
different detection method should be
applied.
E3S-C
Photoelectric sensor
A
B
Min.
Max.
ON
STABILITY
LIGHT
(green)
(red)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents