COMPONENT TESTING (Cont.)
Whirlpool
and KitchenAid
Global Wash SS
®
®
VEE
5 V
L
VDD
12 V
N
POWER
SUPPLY
REF
12 V
Drive
12 V
12 V
Drive
HTR-L
Drive
RELAY
MOTOR
Integ 1P
HTR-N
RELAY
OR
RELAY
FUSE
12 V
Drive
FUSE
OR
SMD
PILOT
RELAY
4
3
2
1
1
2
3
4
P4
WH
BU/WH
BU/RD
BK wire
P5
LT BU
BR
wire
wire
wire
FUSE
(ON SOME
MODELS)
N
L1
M
DRAIN
MOTOR
120 V / 60 Hz
45 W, 0.65 A
L1
N
27 - 33
H.L.STAT
1
2
3
HEATER
120 V / 60 Hz
WASH
800 W WET / 500 W DRY
MOTOR
10 - 40
PUMP
120V / 60Hz
26 - 36 W
7.5 - 9
AT 25°C
Whirlpool
and KitchenAid
VS Wash Motor
®
®
ELECTRONIC CONTROL
VEE
5 V
L
POWER
VDD
12 V
N
SUPPLY
RELAY RETURN LINE THAT GOES THRU DOOR SWITCH
REF
RELAY RETURN LINE THAT BYPASSES DOOR SWITCH
12 V
Triac Load Current Sensing
Drive
12 V
HTR-L
Drive
RELAY
HTR-N
OR
RELAY
12 V
FUSE
Drive
PILOT
SMD
RELAY
Variable Speed Motor Drive
4
3
2
1
1
2
3
4
5
6
P4
P5
LT BU
WH
BU/WH
BU/RD
BK wire
BR
wire
wire
wire
FUSE
(ON SOME
MODELS)
N
L1
M
DRAIN
MOTOR
120 V / 60 Hz
27 - 33
H.L.STAT
1
2
3
HEATER
Variable
Speed
120 V / 60 Hz
Wash
800 W WET / 500 W DRY
Motor
10 - 40
APPROX 60W at 3200 RPM
3-4
n
Whirlpool
and KitchenAid
Filtration and Maytag
®
®
For Service Technician Use Only
Wiring Diagram (Continued)
1
3
4
6
1
3
4
6
1
2
3
4
5
6
7
8
9
P6
BU
P8
PK
P12
VT
VENT
M
120 V / 60 Hz / 6 W
600 - 1800
DISPENSER
SPRAY ARM MOTOR
120 V / 60 Hz
DOOR SW
(ON SOME MODELS)
M
310 - 380
DIVERTER
120V / 60Hz / 6W
12 V
1890 - 2310
NORMALLY
120 V / 60 Hz / 3 W
OPEN
1100 - 1400
FILL VALVE
120 V / 60 Hz / 5 W
1200 - 1600
1
3
4
6
1
3
4
6
1
2
3
4
5
6
7
8
9
P6
BU
P8
PK
P12
VT
VENT
M
120 V / 60 Hz / 6 W
600 - 1800
DISPENSER
SPRAY ARM MOTOR
120 V / 60 Hz
DOOR SW
(ON SOME MODELS)
M
310 - 380
DIVERTER
120V / 60Hz / 6W
12 V
1890 - 2310
EACH COIL
NORMALLY
120 V / 60 Hz / 3 W
OPEN
1100 - 1400
FILL VALVE
120 V / 60 Hz / 5 W
1200 - 1600
24" Microfiltration Dishwashers
®
Door Open
Detection
PWM
INPUT
Analog
Input
10
#
1
2
3
4
5
1
2
3
4
5
6
7
P9
RD
P14
BR
M
MIDDLE SPRAY ARM
SENSOR
FAN MOTOR
(ON SOME MODELS)
12 V, 1 W
LIGHT IN
12 V
THE
(ON SOME MODELS)
TUB
12 V
PWM
Door Open
Detection
PWM
INPUT
Analog
Input
10
#
1
2
3
4
5
1
2
3
4
5
6
7
P9
RD
P14
BR
M
RINSE AID EMPTY &
MIDDLE SPRAY ARM
SENSOR
FAN MOTOR
(ON SOME MODELS)
12 V, 1 W
LIGHT IN
12 V
THE
(ON SOME MODELS)
TUB
12 V
Lower Spray Arm
PWM
Sensor
( On Some Models)
12 V
BEEPER
INPUT
REF
12 V
OPT
TURB
INPUT
INPUT
WIN
INPUT
SIG
DRIVE
DATA
P1B
5 V
1
2
3
4
GY
1
2
3
4
5
6
1
2
3
4
5
6
7
P10
YL
P11 OR
O.W.I.
WiFi module
LEAKAGE
FLOW
(FLOAT)
METER
DIVERTER
OR
SENSOR
12 V
12 V
NORMALLY
12 V
NON-SOIL SENSING
MODELS
12 V
BEEPER
INPUT
REF
12 V
NTC
OPT
TURB
INPUT
INPUT
WIN
INPUT
SIG
DRIVE
P1B
5 V
DATA
1
2
3
4
GY
1
2
3
4
5
6
1
2
3
4
5
6
7
P10
YL
P11 OR
O.W.I.
(NTC & Turbidity Sensor)
WiFi module
LEAKAGE
FLOW
(FLOAT)
METER
DIVERTER
SWITCH
OR
SENSOR
12 V
12 V
NORMALLY
SWITCHED
12 V
CLOSED
SWITCHED
NTC
NON-SOIL SENSING
MODELS
(SEE NTC TABLE BELOW)
( 2 4 8 )
PROGRAMS
OPTION A
OPTION B
START
ALARMS
(DELAY)
Drain
MAX POSSIBLE POPULATION
(SEE TABLE BELOW)
REF
(4p R2.5 header)
12 V
P3
WIN
5 V
DATA
5
P1A
4
GND
1
2
3
4
3
WIN data
TOOL
WH
2
5 V
1
12 V
External HMI
1
2
3
4
1
2
3
GND
Data
12 V 5 V Data GND
5 V
4
3
2
1
ACU DIAGNOSTIC LED
(SEE TABLE BELOW)
REF
(4p R2.5 header)
12 V
P3
WIN
5 V
P1A
DATA
5
Reserved
4
GND
1
2
3
4
3
SERVICE
WIN data
TOOL
WH
2
5 V
1
12 V
External HMI
1
2
3
4
1
2
3
GND
Data
12 V 5 V Data GND
5 V
4
3
2
1
Front Status Display
(On Some Models)

Advertisement

Table of Contents
loading

This manual is also suitable for:

W11447459

Table of Contents