Set-Up And Start-Up - Kendrion EEX Series Operating Instructions Manual

Spring-applied single-disc brake
Table of Contents

Advertisement

3.5 Set-up and start-up

Warning!
Functional testing of the brake must not be performed unless the machine (e.g. motor) has been switched off
and secured against accidental or unintentional start-up.
The following checks must be carried out:
Check compliance with the specifications provided on the rating plate with respect to the mounting position
and protection class. Provided that the mounting surface (mounting side) (8) for the spring-applied single-disc
brake is closed, no further measures need to be taken to ensure compliance with the required protection class.
If the mounting surface (mounting side) (8) is open, adequate sealing must be provided in accordance with the
installation procedure E76 00A0030 000 recommended by Kendrion. This can also be accomplished by using
a sealing device available from Kendrion. In this case, the maximum possible protection rating is IP 56. After
connection of the brake, a functional test must be performed to check that the friction disc (5) moves smoothly.
For this purpose, turn the shaft while the brake is energized and the machine (e.g. motor) is unpowered. After
completion of mounting, all necessary covers and guards must be installed.
Specifications on rating plate (order-specific, example brake type 76 26G11B00):
Voltage frequency
Order number
(product number per order)
Type number
Rated voltage
Certification code
optional, see specific order
IECEx Scheme
EC type-examination certificate
Zone 1:
occasional explosion hazard
Zone 2:
occasional explosion hazard for short periods
Zone 21:
occasional explosion hazard caused by combustible dust in normal operation
Zone 22:
explosion hazard caused by combustible dust unlikely to occur in normal operation; if it does
only for short periods
Note:
The product number of the spring-applied single-disc brake consists of the type number
followed by the version number, e.g. 76 26G11B00-0001.
Version number (4-digit)
Rated current
Max. switching power
Offer drawing index
Rated torque
CE ident. no.
Manufacturing date
and inspector ID
Operating Instructions BA 76..G..B00 // Last updated: 13/03/2020 // Page 17 of 34
Certification codes:
(to IEC/EN 60079-0)
II 2G
group II equipment; category
2G (gas atmospheres);
zones 1 and 2
II 2D
group II equipment; category
2D (combustible dust atmos-
pheres); zones 21 and 22
IIlC
group lll equipment;
C, conductive dust
IP67 T95°C
IP 67 protection; max. surface
temperature 95°C
Ex db eb IIC T5 flameproof enclosure;
increased safety;
group II equipment (electrical
equipment for use in poten-
tially explosive atmospheres
except for underground
mines); classification C (gas
and vapour atmospheres);
temperature class T5 vapour
atmospheres); temperature
class T5
tb
equipment dust ignition
protection by enclosure "t";
enclosure protection
Db
equipment protection level
(EPL): Db
IECEx BVS...
IECEx Scheme number
DMT 02
notified body and certification
year
ATEX E 122 X
certification number

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents