Kendrion 76..P..B00 Series Operating Instructions Manual

Industrial drive system spring-applied single-disc brake

Advertisement

Quick Links

Types: 76 14P10B00 76 16P10B00
76 14P11B00 76 16P10B00
76 14P13B00 76 16P13B00
76 14P16B00 76 16P16B00
76 14P19B00 76 16P19B00
76 14P24B00 76 16P24B00
Operating Instructions 76 ..P..B00
Spring-applied single-disc brake
with dust and firedamp protection I
76 24P10B00
76 24P11B00
76 24P13B00
76 24P16B00
76 24P19B00
76 24P24B00
EEX LINE
76 26P10B00
76 26P11B00
76 26P13B00
76 26P16B00
76 26P19B00
76 26P24B00

Advertisement

Table of Contents
loading

Summary of Contents for Kendrion 76..P..B00 Series

  • Page 1 EEX LINE Operating Instructions 76 ..P..B00 Spring-applied single-disc brake with dust and firedamp protection I Types: 76 14P10B00 76 16P10B00 76 24P10B00 76 26P10B00 76 14P11B00 76 16P10B00 76 24P11B00 76 26P11B00 76 14P13B00 76 16P13B00 76 24P13B00 76 26P13B00 76 14P16B00 76 16P16B00 76 24P16B00 76 26P16B00...
  • Page 2: Table Of Contents

    Product versions (types) ........................30 Authorised repair shops for maintenance work ................30 Issued by: Kendrion Binder Magnete GmbH Industrial Drive Systems Replaces the issue dated: 10 June 2008 Translation of original German operating instructions issue dated: 30 December 2009 Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00...
  • Page 3: General Information

    Kendrion Binder and ask for clarification before starting to use the brake. Kendrion Binder spring-applied brakes in the 76 ..P..B00 series are not ready-to-use devices, but are intended to be incorporated into or assembled with other equipment.
  • Page 4: Declaration Of Incorporation (In Accordance With Annex Ii, Part 1, Section B Of Machinery Directive 2006/42/Ec)

    Annex VII, part B of Machinery Directive 2006/42/EC. The manufacturer undertakes to submit an electronic copy of the relevant technical documentation compiled for the partly completed machinery if reasonably requested by national authorities. Manufacturer: Kendrion Binder Magnete GmbH Person authorised Dr. Matthias Dannemann Industrial Drive Systems...
  • Page 5: Product Description

    Thermoswitch (2 switches) Spring washer Machine screw Microswitch Machine screw Friction plate 13.1 Locknut Spring washer Rating plate 13.2 Set screw O-ring Compression spring Duct Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 5...
  • Page 6 Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 6...
  • Page 7: Installation

    The M tightening torque specified for the fixing screws (10) must be strictly observed. The screws (10) must be tightened evenly in diametrically opposite sequence. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 7...
  • Page 8: Installation Of The Hand Release (29) (Brakes Types With Hand Release)

    (29) and automatic return of the hand release lever in its central position (see Fig. 6/1) has been ensured. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009...
  • Page 9: Electrical Connection And Operation

    Perfect brake operation must be ensured by the user or system manufacturer by providing suitable electrical controls. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009...
  • Page 10: Ac Power Supply

    DC side. The jumper on the connecting terminal (19) (see Fig. 9/2) must be replaced by the auxiliary contact. In case of DC side switching, AC side switching is also required. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009...
  • Page 11 AC side switching DC side switching Fig. 11/1: Suggested wiring of brake and safety switches (circuit diagram) Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 11...
  • Page 12: Microswitch (13) And Thermoswitch (11 And 12) Connection

    When fixing the cover (26) to the connector box (25), the M tightening torques of the machine screws specified in Table 13/1 must be strictly observed. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 12...
  • Page 13 (e.g. motors) without load torque impact. When the brake is used for applications during which a load torque is generated, the system user is responsible to ensure correct and safe wiring of the microswitch (13) and spring-applied single-disc brake. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009...
  • Page 14: Electromagnetic Compatibility

    Voltage dips and supply voltage variations to below the minimum tolerance threshold will cause torque reductions. The user is required to take adequate precautions to avoid consequential damage. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009...
  • Page 15 Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009...
  • Page 16: Set-Up And Start-Up

    If the fixing surface (mounting side) (8) is open, adequate sealing must be provided in accordance with the Kendrion Binder recommended installation procedure E76 00A0030 000. In this case, the maximum possible protection rating is IP 56. After connection of the brake, an operational test must be performed to check that the friction disc (5) runs smoothly.
  • Page 17: M 2 Rated Torque Adjustments

    1 mm axial adjustment of the machine screw (32); permitted projection x Warning! Any adjustment of the rated torque must be performed by the manufacturer's authorised personnel. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 17...
  • Page 18: Maintenance

    Attention! Make sure that the connections of the four thermoswitches (11 and 12) are not damaged or loosened when removing the flange (3). Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 18...
  • Page 19 (11 and 12). Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009...
  • Page 20 An oily or greasy friction disc (5) cannot be cleaned. • the friction lining has not swollen or turned vitreous. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009...
  • Page 21: Spare Parts And Accessories

    Caution! Risk of burns in case of contact with hot surfaces! Suitable covers and hand guards must be installed to provide protection against accidental contact. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 21...
  • Page 22: Troubleshooting

    • Check the spring force. Install a new brake, if necessary. Broken compression spring Table 22/1: Possible faults, causes and corrective actions (list not exhaustive) Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 22...
  • Page 23: Safety

    Kendrion Binder and ask for clarification before using the brake. Retrofitting or modification work to be carried out on the brake is subject to the approval from Kendrion Binder.
  • Page 24: Set-Up And Start-Up

    Make sure that no voltage is applied to the brakes when carrying out maintenance work. Danger! The warning "DO NOT OPEN WHILE ENERGISED" affixed to the spring-applied single-disc brake must be strictly observed. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 24...
  • Page 25: Warning Symbols

    Attention damage equipment Information Symbol / Term Provides information on … Note the safe use and operation of the product Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 25...
  • Page 26: Definitions

    Operating condition at operating temperature condition at which the steady-state temperature is reached. The operating temperature corresponds to the overtemperature according to DIN VDE 0580 plus the ambient temperature. Unless otherwise specified, the ambient temperature is 35°C. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 26...
  • Page 27 Rated power at 20°C winding temperature P components and the R resistance at 20°C winding temperature Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 27...
  • Page 28: Technical Specifications

    [mm] 0.05 to 0.1 Min. overtravel [mm] Contact type normally open Temperature range [°C] -20 to +100 Table 28/2: Microswitch specifications (only brakes with microswitch) Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 28...
  • Page 29 Z process has been completed (see Table 30/1). Vertical (values based on n=1500 rpm) brake operation is only allowed after prior consultation with the manufacturer. Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00 Last updated: 30 Dec. 2009 Page 29...
  • Page 30: Product Versions (Types)

    Mönchweilerstr. 1 78048 Villingen-Schwenningen Germany Tel. +49 (0)7721 877-1417 Fax +49 (0)7721 877-1462 United Kingdom Kendrion Binder Magnete (UK) Ltd. Huddersfield Road, Low Moor Bradford, West Yorkshire, BD12 0TQ Tel. +44 (0)1274 601111 Fax +44 (0)1274 691093 Kendrion Binder Magnete GmbH Operating Instructions 76 ..P..B00...