PV Grid Tie Inverter Solis 4G Mini Single Phase Inverter Installation and Operation Manual Solis-mini-700-4G, Solis-mini-1000-4G, Solis-mini-1500-4G, Solis-mini-2000-4G, Solis-mini-2500-4G, Solis-mini-3000-4G, Solis-mini-3600-4G, Solis-mini-1000-4G-LV Ginlong Technologies Co., Ltd. No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 315712, P.R.China. Tel: +86 (0)574 6578 1806 Fax: +86 (0)574 6578 1606 Please adhere to the actual products in case of any discrepancies in this user manual.
……………………………… 1.1 Product Description 6.4.2 Running Message …………………………… Solis 4G Mini Single Phase Inverter integrate DRM and backflow power control function, thatcould suitable for smart grid requirement. ………………………………………… 6.4.3 Version Mini Single phase 4G series inverter contain 8 models which are listed below: 6.4.4 Daily Energy...
Solis -m ini-7 00-4 G, S olis -m ini-1 000-4 G, Solis -m ini-1 500-4 G, S olis -m in i-2 000-4 G, Solis -m ini-2 500-4 G, Solis -m ini-3 000-4 G, S olis -m in i-3 600-4 G, S olis -m in i-1 000-4 G-LV CAUTION, RISK OF ELECTRIC SHOCK symbol indicates important safety instructions, which if not correctly followed, could result in electric shock.
The DC OCPD shall be installed per local requirements. All photovoltaic source and output circuit conductors shall have disconnects that comply with the NEC Article 690, Part II. All Solis 4G Mini Single Phase Inverters feature an integrated DC switch.
3. Overview 4. Installation 3.3 Keypad 4.1 Select a Location for the Inverter To select a location for the inverter, the following criteria should be considered: There are four keys in the front panel of the Inverter(from left to right): WARNING: Risk of fire ESC, UP, DOWN and ENTER keys.
4. Installation 4. Installation 4.2 Mounting the Inverter Dimensions of wall bracket: Install vertically with a maximum incline of +/- 5°.If the mounted inverter is tilted to an angle greater than the maximum noted, heat dissipation can be inhibited, and may result in less than expected output power.
Hang the inverter on the Maximum 600Voc for mounting bracket and make sure the inverter is secure (see Figure 4.5). Solis-mini-700-4G, Solis-mini-1000-4G, Solis-mini-1500-4G, Solis-mini-2000-4G, Solis-mini-2500-4G, Solis-mini-3000-4G, Solis-mini-3600-4G, Solis-mini-1000-4G-LV Please don’t connect PV array positive or negative pole to the ground, it could...
Page 9
4. Installation 4. Installation iv) Insert the contact pin to the top part of the connector and screw up the cap nut to Cross section Cable type the top part of the connector. Recommended Range value Industry generic PV cable 4.0~6.0 4.0(12AWG)...
Figure 4.13 AC Grid Terminal Connector Inside Figure 4.16 Connect Wires to the Terminal Each Solis 4G Mini Single Phase Inverter is supplied with an AC grid terminal connector. c) Tighten up the cap on the terminal (see Figure 4.17).
Prepare OT terminals: M4. Use proper tooling to crimp the lug to the terminal. The inverter can be monitored via Wi-Fi or GPRS. All Solis communication devices are optional (Figure 4.20). For connection instructions, please refer to the Solis Monitoring Device installation manuals.
Direct Insert Type Meter - Max input current 60A (Model:DDSD1352-C) External CT Type Meter - 120A/40mA CT is supplied (Model: ACR10RD16TE) Load Customer can place the order for a suitable meter from Solis Sales Reps. N PE Below are the connection diagrams of different meters connecting to different locations.
Meter Model can only connect a smart meter. Pre-made Cable in Meter Package RJ45 Connector CT Model can only connect a smart sensor. 5 6 7 8 9 10 21 22 23 Please consult Solis Sales Rep before placing the order. White Black NOTE:...
4. Installation 5. Start & Stop 5.1 Start the Inverter 4.3.9 Logic interface connection (For UK and Belgium) Logic interface is required by Logic interface is required by local regulations in UK and To start up the Inverter, it is important that the following steps are strictly followed: Belgium that can be operated by a simple switch or contactor.
NULL 10 sec 6.2 Information DRM Number: DRM Number:Show the number 01-08. The Solis 4G Mini Single Phase Inverter main menu provides access to operational data and Meter EnergyP Meter EnergyP:The active power. 10 sec 0000000.00k information. The information is displayed by selecting "Information" from the menu and then by scrolling up or down.
This function is used to set the address when muti inverters are connected to single monitor. Time: 00-00 Data: 0000 The address number can be assigned from “01”to “99”. Figure 6.6 Alarm Message The default address number of Solis 4G Mini Single Phase Inverter is “01”. 6.4.2 Running Message YES=<ENT> NO=<ESC> Set Address: 01 This function is for maintaince person to get running message such as internal temperature, Standard NO.
6. Operation 6. Operation 6.4.3 Version 6.4.6 Yearly Energy The function is for checking the energy generation for selected year. The screen shows the model version and the software version of the Inverter . YES=<ENT> NO=<ESC> Model: 08 Select: 2020 Software Version: D20001 Figure 6.12 Select year for yearly energy Figure 6.7 Model Version and Software Version...
This function is used to select the grid's reference standard (see Figure 6.16). 6.5.2 Grid ON/OFF YES=<ENT> NO=<ESC> Standard:AS4777-02 This function is used to start up or stop the power generation of Solis Single Phase Inverter. Figure 6.16 Grid ON Press the UP/DOWN keys to select the standard (AS4777-02,AS4777-15, VDE4105, VDE0126, Grid OFF UL-240V-A, UL-208V-A, UL-240V, UL-208V, MEX-CFE, G83/2 (for 1-3.6kW models), G59/3...
6. Operation 6. Operation 6.5.4 Clear Energy 6.5.8 Special Settings Clear Energy can reset the history yield of inverter This function is applicable by maintenance personnel only, wrong operation will prevent the inverter from working properly. These two functions are applicable by maintenance personnel only, wrong operation will prevent the inverter from working properly.
If customer does not want to enable the export power control function, please for the whole day and the data will be displayed on the Solis monitoring system. change the "backflow power" to the max output power of the inverter in Step 5 Smart meter can only be installed on the grid side.
Page 21
This setting is used to define the CT sampling ratio if customer didn't use the default CT supplied by Solis. NOTE: The default CT is 100A:33.33mA (Default ratio is 3000:1) Positive values indicate the amount of power is allowed to export to the grid.
This function is used for calibrate inverter output energy. It will not impact the energy count corresponding meter model. for inverter with RGM. The screen shows: 6.5.13 External EPM Set This setting should only be turned on when Solis external EPM device is used. YES=<ENT> NO=<ESC> Two options are available:5G-EPM and Others-EPM. Power para:1.000 ->5G-EPM Figure 6.27 Power Rate Limit...
Alarm Message Failure description Solution 1.Check PV input connections Solis 4G Mini Single Phase Inverter does not require any regular maintenance. Inverter no power 2.Check DC input voltage No power However, cleaning the dust on heat-sink will help the inverter to dissipate the heat and on LCD (single phase >120V, three phase >350V)
Self consumption (night) <1 W(Night) 1. Serial number of Solis 4G Mini Single Phase Inverter; Operating ambient temperature range -25℃...+60℃ 2. The distributor/dealer of Solis 4G Mini Single Phase Inverter (if available); Relative humidity 0~100% 3. Installation date. Ingress protection...
Page 25
Model Solis-mini-1000-4G Model Solis-mini-1500-4G Max. DC input voltage (Volts) Max. DC input voltage (Volts) Rated DC voltage (Volts) Rated DC voltage (Volts) Start-up voltage (Volts) Start-up voltage (Volts) MPPT voltage range (Volts) MPPT voltage range (Volts) 50...500 50...500 Max. input current (Amps) Max.
Page 26
Model Solis-mini-2000-4G Model Solis-mini-2500-4G Max. DC input voltage (Volts) Max. DC input voltage (Volts) Rated DC voltage (Volts) Rated DC voltage (Volts) Start-up voltage (Volts) Start-up voltage (Volts) MPPT voltage range (Volts) MPPT voltage range (Volts) 80...500 80...500 Max. input current (Amps) Max.
Page 27
Model Solis-mini-3000-4G Model Solis-mini-3600-4G Max. DC input voltage (Volts) Max. DC input voltage (Volts) Rated DC voltage (Volts) Rated DC voltage (Volts) Start-up voltage (Volts) Start-up voltage (Volts) MPPT voltage range (Volts) MPPT voltage range (Volts) 80...500 80...500 Max. input current (Amps) Max.
Page 28
Model Solis-mini-1000-4G-LV Max. DC input voltage (Volts) Rated DC voltage (Volts) Start-up voltage (Volts) MPPT voltage range (Volts) 50...500 Max. input current (Amps) Max short circuit input current (Amps) 17.2 MPPT number/Max input strings number Rated output power (Watts) 1000 Max.