SOLIS -1P1K-4G Installation And Operation Manual

SOLIS -1P1K-4G Installation And Operation Manual

Pv grid tie 4g single phase inverter
Hide thumbs Also See for Solis-1P1K-4G:

Advertisement

Quick Links

Ningbo Ginlong Technologies Co., Ltd.
No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo,
Zhejiang, 315712, P.R.China.
Tel: +86 (0)574 6578 1806
Fax: +86 (0)574 6578 1606
If you encounter any problem on the inverter, please find out the inverter S/N
and contact us, we will try to respond to your question ASAP.
PV Grid Tie Inverter
Solis 4G Single Phase Inverter
Installation and Operation Manual
Solis-1P1K-4G, Solis-1P1.5K-4G, Solis-1P2K-4G, Solis-1P2.5K-4G,
Solis-1P3K-4G, Solis-1P3.6K-4G, Solis-1P4K-4G,
Solis-1P4.6K-4G,Solis-1P5K-4G,Solis-1P6K-4G
2016, Ningbo Ginlong Technologies Co., Ltd.
C
Ver 1.3

Advertisement

Table of Contents
loading

Summary of Contents for SOLIS Solis-1P1K-4G

  • Page 1 PV Grid Tie Inverter Solis 4G Single Phase Inverter Installation and Operation Manual Solis-1P1K-4G, Solis-1P1.5K-4G, Solis-1P2K-4G, Solis-1P2.5K-4G, Solis-1P3K-4G, Solis-1P3.6K-4G, Solis-1P4K-4G, Solis-1P4.6K-4G,Solis-1P5K-4G,Solis-1P6K-4G Ningbo Ginlong Technologies Co., Ltd. No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 315712, P.R.China. Tel: +86 (0)574 6578 1806...
  • Page 2: Table Of Contents

    Contents 1. Introduction ……………………………………………… 1.1 Product Description ………………………………… 1.2 Packaging ………………………………………… 2. Safety Instructions ……………………………………… 2.1 Safety Symbols …………………………………… 2.2 General Safety Instructions ……………………… 2.3 Notice For Use ……………………………………… 3. Overview ……………………………………………… 3.1 Front Panel Display ……………………………… 3.2 LED Status Indicator Lights ………………………...
  • Page 3: Introduction

    Lock screen …………………………………… 6.3 Settings ……………………………………………… Solis 4G single phase inverters integrate DRM and backflow power control function, that could suitable for smart grid requirement. 6.3.1 Set Time ……………………………………… Single phase 4G series inverter contain 10 models which are listed below: 6.3.2 Set Address...
  • Page 4: Packaging

    CAUTION, RISK OF ELECTRIC SHOCK symbol indicates important safety instructions, which if not correctly followed, could result in electric shock. PV Grid Tie Inverter Solis 4G Single Phase Inverter Installation and Operation Manual CAUTION: CAUTION, HOT SURFACE symbol indicates safety instructions, which if not correctly followed, could result in burns.
  • Page 5: Notice For Use

    Inverter. The DC OCPD shall be installed per local requirements. All photovoltaic source and output circuit conductors shall have disconnects that comply with the NEC Article 690, Part II. All Solis single phase inverters feature an integrated DC switch. CAUTION: Risk of electric shock.
  • Page 6: Keypad

    3. Overview 4. Installation 3.3 Keypad 4.1 Select a Location for the Inverter To select a location for the inverter, the following criteria should be considered: There are four keys in the front panel of the Inverter(from left to right): Do not install in small closed spaces where air can not circulate freely.
  • Page 7: Mounting The Inverter

    4. Installation 4. Installation 4.2 Mounting the Inverter Installonawallorstrongstructurecapableofbearingtheweight. Dimensions of wall bracket: Install vertically with a maximum incline of +/- 5°.If the mounted inverter is tilted to an angle greater than the maximum noted, heat dissipation can be inhibited, and may result in less than expected output power.
  • Page 8: Electrical Connections

    Hang the inverter on the within the limit of the inverter mounting bracket and make sure the inverter is secure (see Figure 4.5) Maximum 550Voc for Solis-1P1K-4G Solis-1P1.5K-4G Solis-1P2K-4G Solis-1P2.5K-4G Maximum 600Voc for Solis-1P3K-4G Solis-1P3.6K-4G Solis-1P4K-4G Locking screws Solis-1P4.6K-4G Solis-1P5K-4G Solis-1P6K-4G...
  • Page 9 4. Installation 4. Installation iii) Crimp the contact pin to the wire using a proper wire crimper. Please use approved DC cable for PV system. Cross section Cable type Recommended Range value 4.0~6.0 Industry generic PV cable 4.0(12AWG) (model:PV1-F) (12~10AWG) Table 4.1 DC cable Figure 4.10 Crimp the contact pin to the wire The steps to assemble the DC connectors are listed as follows:...
  • Page 10: Connect Grid Side Of Inverter

    Figure 4.16 Connect Wires to the Terminal c) Tighten up the cap on the terminal (as shown in Figure 4.15). Each Solis Single Phase Inverter is supplied with an AC grid terminal connector. Figure 4.17 Tighten up the Cap on the Terminal Figure 4.14 AC Grid Terminal Connector...
  • Page 11: External Ground Connection

    Table 4.3 Rating of grid OCPD 4.3.5 Inverter monitoring connection The inverter can be monitored via Wi-Fi or GPRS. All Ginlong Solis communication devices are optional (Figure 4.9). For connection instructions, please refer to the Ginlong Solis Monitoring Device installation manuals.
  • Page 12: Electrical Connection Diagram

    4. Installation 4. Installation 1. The RCD should not be placed between the consumers mains and the solar supply. Smart phone monitoring 2. More than one RCD may be used. Each RCD can protect one or more circuits. GPRS monitoring 4.3.7 CT connections(optional) This inverter has integrated export limitation functionality.
  • Page 13: Start & Stop

    4. Installation 5. Start & Stop 5.1 Start the Inverter NOTE: To start up the Inverter, it is important that the following steps are strictly followed: Ginlong 4G inverter is designed to provide 12V power for DRED. 1. Switch the grid supply main Switch (AC) ON first. Please follow below steps to assemble Rj45 connector.
  • Page 14: Operation

    Table 6.1 Information list 4. Advanced Settings 6.2 Information The Solis Single Phase 4G Inverter main menu provides access to operational data and information. The information is displayed by selecting "Information" from the menu and then by scrolling up or down.
  • Page 15: Lock Screen

    The address number can be assigned from “01”to “99”(see Figure 6.4). The default address manually by pressing the UP/ DOWN keys. Press the ESC key to return to the previous number of Solis Single Phase Inverter is “01”. menu. Alarm001: OV-G-V Time: 27-11 Data: 7171 Figure 6.6 Alarm Message...
  • Page 16: Running Message

    6. Operation 6. Operation 6.4.2 Running Message Press DOWN key to move the cursor, press UP key to change the digit. Press Enter after the month/year is fixed. This function is for maintaince person to get running message such as internal temperature, Standard NO.
  • Page 17: Grid On/Off

    6.5.2 Grid ON/OFF UL-208V-A, UL-240V, UL-208V, MEX-CFE, G83/2 (for 1-3.6kW models), G59/3 (for 4-5kW This function is used to start up or stop the power generation of Solis Single Phase models), EN50438 DK, EN50438 IE, EN50438 NL and “User-Def” function). Press the Inverter (see Figure 6.17).
  • Page 18: Calibrate Energy

    This sub menu is enabled when the grid standard is set to AS4777. To comply with New AUS/ Set P_Limit2: 20%-100%, Default 100% NZ 4777.2, Ginlong Solis 4G inverter could set different work mode to work with different Set Voltage3: 235-255V, Default 250V grid requirement.
  • Page 19: Set Backflow Power

    6. Operation 6. Operation The other 3 setting in AUS STD. setting are as below: 6.5.8.2 CT Sampling Ratio 1. Power Rate limit Wgra: 0-100%, Default 16% This function is used for change CT Sampling Ratio if customer select different CT. 2.
  • Page 20: Ct Link Test

    7. Maintenance 6.5.8.4 CT Link Test 7.Maintenance Solis Single Phase Inverter does not require any regular maintenance. However, cleaning Before pressing the CT Link Test menu, please check as follow: 1.Load power ≥ 500W the dust on heat-sink will help the inverter to dissipate the heat and increase its life time.
  • Page 21: Troubleshooting

    1. Serial number of Solis Single Phase Inverter; Over DC voltage OV-DC01/02/03/04 1.Reduce the module number in series Over DC bus voltage 2. The distributor/dealer of Solis Single Phase Inverter (if available); OV-BUS 1.Check inverter inductor connection 2.Check driver connection Under DC bus voltage 3.
  • Page 22: Technical Data

    9.1 Technical data Solis-1P2K-4G GCI-1P2.5K-4G Model 3000 2300 Max power per MPPT (Watts) Model Solis-1P1K-4G Solis-1P1.5K-4G Max voltage (Volts) Max power per MPPT (Watts) 1800 1200 Startup voltage (Volts) Max voltage (Volts) Operating MPPT voltage range (Volts) 50...450 Startup voltage (Volts) Max.
  • Page 23 Model Solis-1P3K-4G Solis-1P3.6K-4G Model Solis-1P4K-4G Solis-1P4.6K-4G Max power per MPPT (Watts) 3500 4000 Max power per MPPT (Watts) 4000 Max voltage (Volts) Max voltage (Volts) Startup voltage (Volts) Startup voltage (Volts) Operating MPPT voltage range (Volts) 90..520 Operating MPPT voltage range (Volts) 90...520...
  • Page 24 Model Solis-1P5K-4G Solis-1P6K-4G Max power per MPPT (Watts) 4000 Max voltage (Volts) Startup voltage (Volts) Operating MPPT voltage range (Volts) 90...520 Max. Inverter Backfeed Current to the Array (Adc) Max usable input current per MPPT (Amps) 11+11 Max short circuit input current (Amps) 17.2+17.2...