10.0 Connectors and Controls
10.1 AC Power
AC Mains Inlet:
AC Mains Cord required:
Fuse type:
10.2 DC Power
The CueScript prompters require a regulated supply of 12 volts DC rated at 4 amps. Alternatively, a
battery with sufficient capacity may be used. The prompter is designed to operate in the range 9V –
18V DC.
Prompter Connector type:
Mating (cable) connector:
10.3 Composite Video In
Prompter Connector type:
Mating (source) connector:
Pin
Center
Outer
IEC socket with built in fuseholder and lighted ON/OFF switch
Three wire 18 Gauge conductors with IEC socket and country
appropriate plug. Safety ratings such as UL or TUV are preferred.
5X20mm Fast acting glass fuse rated at 3A 250V AC.
Example fuse: Littelfuse part no.
The fuse must only be replaced with one of the same type and current
rating.
4 pin XLR Male plug
4 pin XLR Female socket
Pin
Description
1
GROUND (connected to monitor chassis)
2
No Connection
3
No Connection
4
+12V DC
75 Ohm BNC Socket
75 Ohm BNC Plug
Description
Composite Video In (PAL, NTSC, or
SECAM)
Ground