15. Unscrew completely the handwheel (129634).
16. Insert a rod or tool (116236) into the insert (threaded
side) and push out the valve seat assembly. Separate
the components of the valve seat. Use your fingernail to
remove the seat and the small O-ring of the shuttle
valve.
17. Remove the o-ring (AP1438).
18. Unscrew the seat 6 or 7 turns using a screwdriver. Push
the plastic part of tool (116236) into the insert to push
out the seat. Remove the seat O-ring.
Service manual Legend LX – LUX second stage
Rev. 12/2011
Legend LX LUX second stage service manual
19. Use the tool (125727 or 129001) to unscrew the plug.
Remove the handwheel from the adjusting screw.
20. Use a 4 mm Allen key to remove the screw.