Aqua Lung LEGEND LX Service Manual page 15

Hide thumbs Also See for LEGEND LX:
Table of Contents

Advertisement

25. Fit the front cover (129676 or 129777) onto the casing :
25.1 Set the Front cover.
25.2 Pull up the pin
locker.
25.3 Rotate the cover
clockwise.
25.4 Release the pin
Check that the pin
goes through the
casing hole.
Note: If you have a regulator Test Bench, carry
out these tests before refitting the mouthpiece.
Instructions for the check are given in the
paragraph Final Checks
28. Turn off the air supply and purge the second stage.
Remove the tool 122046+122041. Tighten the hose nut using
an 11/16" spanner.
Service Manual Legend LX – LUX second stage
Rev. 12/2011
Legend LX LUX second stage service manual
29. Refit the mouthpiece onto the casing. If it is a Comfobite
mouthpiece, check that the support section is on top. Fit
the mouthpiece strap into its groove. The collar lever
should point down on the hose side.
30. Push out the pin locker with the seat extractor tool (
P/N 116236) to fit the exhaust baffle (129732).
Attention: Make sure the pin locker is set back
into the hole.
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Legend luxLegend lux supremeLegend lx supreme