6.
Into the insert, holding the lever at right angles to the
insert. Push the shuttle valve in until it passes the notch.
To check that it is correctly fitted, turn the insert over,
the shuttle valve should stay inside.
7.
Fit a new lubricated o-ring (122135) into the screw
(129632).
8.
fit a new lubricated o-ring (124702) into the screw
groove (129628).
9.
Using a 4mm Allen key , fit fully the screw (129632)
into the screw (129628)
Adjust as follows:
a.
Legend LX and Legend LUX :
Unscrew two and half turns.
Service Manual Legend LX – LUX second stage
Rev. 12/2011
Legend LX LUX second stage service manual
b.
Legend LX Supreme and LUX Supreme:
Unscrew two turns.
10. Fit the adjusting handwheel (129634) onto the adjusting
screw. Use tool (125727) to screw the plug fully home
on the adjusting screw.
Attention: Before screwing in the plug, turn it anti-
clockwise to first engage the thread. Take care not
to damage the plastic threads.
11. Screw fully home the handwheel into the valve spindle.
The lever should now be under tension (due to the
spring). Fit the key (129637) into its groove.