1.2.1. MPLH0XS0 / MSLH0XS0, MPLHEXS0 / MSLHEXS0
This manifold is available in brass chrome plated (MPL...) and stainless steel (MSL...). It consists of the follow-
ing components:
Pressure regulator with inlet pressure & outlet pressure gauge
Option -0: 4-Port adapter to connect coil or hose
Relief valve
Front plate and ground plate
EN
Option –S: 4-Port Shut-o valve at outlet
SPECIALS
S: safety valve at outlet
C: check valves at inlets
U: safety valve at outlet and check valves at inlets

1.2.2. MPLH0XSS / MSLH0XSS, MPLHEXSS / MSLHEXSS

This manifold is available in brass chrome plated (MPL...) and stainless steel (MSL...). It consists of the follow-
ing components:
Pressure regulator with inlet pressure & outlet pressure gauge
Option -S: 4-Port shut-o valve at inlet
Relief valve
Front plate and ground plate
Option –S: 4-Port Shut-o valve at outlet
SPECIALS
S: safety valve at outlet
C: check valves at inlets
U: safety valve at outlet and check valves at inlets

1.2.3. MPLH0XSP / MSLH0XSP, MPLHEXSP / MSLHEXSP

This manifold is available in brass chrome plated (MPL...) and stainless steel (MSL...). It consists of the follow-
ing components:
Pressure regulator with inlet pressure & outlet pressure gauge
Option -P: Purge valve for process gas purging and 4-Port shut-o valve at inlet
Relief valve
Front plate and ground plate
Option –S: 4-Port Shut-o valve at outlet
SPECIALS
S: safety valve at outlet
C: check valves at inlets
U: safety valve at outlet and check valves at inlets

1.2.4. MSLH0XSE, MSLHEXSE

This manifold is only available in stainless steel. It consists of the following components:
Pressure regulator with inlet pressure & outlet pressure gauge
Option -E: three 4-port purge valves for inert gas purging including 4-port shut-o valve at inlet
Relief valve
Front plate and ground plate
Option –S: 4-Port Shut-o valve at outlet
SPECIALS
S: safety valve at outlet

1.3. EXPLANATION OF SYMBOLS

SAFETY INFORMATION
Safety information is highlighted by symbols in these instruc-
tions. This safety information is preceded by signal words that
defi ne the extent of risk.
DANGER!
This combination of symbol and signal word indicates an im-
mediately dangerous situation that will cause death or severe
injury if not avoided.
6/68

Advertisement

Chapters

Table of Contents
loading

Related Products for GCE druva MPLH0XS0

This manual is also suitable for:

Mslh0xs0Mplhexs0Mslhexs0

Table of Contents