Overview - Mslh0Xspsu, Mslhexspsu - Full Version; Overview - Mslh0Xsess, Mslhexsess - Full Version; Brief Description Mplh0Xs / Mslh0Xs, Mplhexs / Mslhexs - GCE druva MPLH0XS0 Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

4.6. OVERVIEW
MSLH0XSPSU, MSLHEXSPSU
FULL VERSION
EN
4.7. OVERVIEW
MSLH0XSESS, MSLHEXSESS
FULL VERSION

4.8. BRIEF DESCRIPTION MPLH0XS / MSLH0XS, MPLHEXS / MSLHEXS

With the manifold type MPLH0X, MPLHEX... (material: brass chrome plated) an industrial, non-toxic and
non-corrosive gas or gas mixture, which is stored inside gas cylinder or bundle with over pressure can be
reduced from maximum 300 bar tubing pressure (3 bar, 6 bar, 10 bar, 14 bar, 28 bar, 50 bar, 100 bar, 200 bar).
With the manifold type MSLH0X, MSLHEX...(material: stainless steel) additional toxic and corrosive gases
which is stores inside gas cylinder or bundle with over pressure can be reduced from maximum 300 bar tub-
ing pressure (3 bar, 6 bar, 10 bar, 14 bar, 28 bar, 50 bar, 100 bar, 200 bar).
A relief valve at pressure regulator secures the manifold with its outlet pressure against incorrect pressure
rising at the outlet due to leakage in regulator seat.
Additional components could be outlet shut o valve, safety valve and/ or check valve.
The real inlet and outlet pressure of the manifold is displayed at the pressure gauges. There is the possibility
to use contact gauges for inlet and outlet pressure.
If the manifold has the opportunity for process gas purging, this can be done before initial start-up to remove
contaminates. Furthermore it is possible to depressurize the high pressure side before cylinder is changed.
If the manifold has the opportunity for inert gas purging (MSLH0XSE, MSLHEXSE), the high pressure area
of the manifold can be purged to remove contaminates before initial start-up or before cylinder or bundle
change. The manifold version with inert gas purging is only available in stainless steel.
The described system is mounted on a stainless steel plate. Due to plate dimensions all components are pro-
tected against damage inside of package, during transport and in mounted condition. The two plates design
enables to mount the component easy and with less weight.