Parameter list

 Parameter list (by parameter number)
For simple variable-speed operation of the inverter, the initial values of the parameters may be used as they are. Set the necessary
parameters to meet the load and operational specifications. Parameter setting, change, and check can be made on the operation panel.
NOTE
• The changing of the parameter settings may be restricted in some operating statuses. Use Pr.77 Parameter write selection to change the
setting.
Pr.
Function
Pr.
group
0
G000
1
H400
2
H401
3
G001
4
D301
5
D302
6
D303
7
F010
8
F011
9
H000
10
G100
11
G101
12
G110
13
F102
15
D200
16
F002
17
T720
18
H402
19
G002
20
F000
22
H500
23
H610
24
D304
to
to
27
D307
29
F100
30
E300
31
H420
32
H421
33
H422
34
H423
35
H424
36
H425
40
E202
41
M441
42
M442
43
M443
Name
Torque boost
Maximum frequency
Minimum frequency
Base frequency
Multi-speed setting (high speed)
Multi-speed setting (middle speed)
Multi-speed setting (low speed)
Acceleration time
Deceleration time
Electronic thermal O/L relay
DC injection brake operation frequency
DC injection brake operation time
DC injection brake operation voltage
Starting frequency
Jog frequency
Jog acceleration/deceleration time
MRS input selection
High speed maximum frequency
Base frequency voltage
Acceleration/deceleration reference
frequency
Stall prevention operation level
Stall prevention operation level
compensation factor at double speed
Multi-speed setting (speed 4 to speed 7)
Acceleration/deceleration pattern selection
Regenerative function selection
Frequency jump 1A
Frequency jump 1B
Frequency jump 2A
Frequency jump 2B
Frequency jump 3A
Frequency jump 3B
RUN key rotation direction selection
Up-to-frequency sensitivity
Output frequency detection
Output frequency detection for reverse
rotation
Minimum
Setting range
setting
increment
0 to 30%
0.1%
0 to 120 Hz
0.01 Hz
0 to 120 Hz
0.01 Hz
10 to 400 Hz
0.01 Hz
0 to 400 Hz
0.01 Hz
0 to 400 Hz
0.01 Hz
0 to 400 Hz
0.01 Hz
0 to 3600 s
0.1 s
0 to 3600 s
0.1 s
0 to 500 A
0.01 A
0 to 120 Hz
0.01 Hz
0 to 10 s
0.1 s
0 to 30%
0.1%
0 to 60 Hz
0.01 Hz
0 to 400 Hz
0.01 Hz
0 to 3600 s
0.1 s
0, 2, 4
1
120 to 400 Hz
0.01 Hz
0 to 1000 V, 8888, 9999
0.1 V
1 to 400 Hz
0.01 Hz
0 to 200%
0.1%
0 to 200%, 9999
0.1%
0 to 400 Hz, 9999
0.01 Hz
0, 2
1
0, 2
1
0 to 400 Hz, 9999
0.01 Hz
0 to 400 Hz, 9999
0.01 Hz
0 to 400 Hz, 9999
0.01 Hz
0 to 400 Hz, 9999
0.01 Hz
0 to 400 Hz, 9999
0.01 Hz
0 to 400 Hz, 9999
0.01 Hz
0, 1
1
0 to 100%
0.1%
0 to 400 Hz
0.01 Hz
0 to 400 Hz, 9999
0.01 Hz
Initial
Customer
value
setting
6%
∗1
4%
∗1
3%
∗1
2%
∗1
120 Hz
0 Hz
50 Hz
50 Hz
30 Hz
10 Hz
5 s
∗2
10 s
∗2
15 s
∗2
5 s
∗2
10 s
∗2
15 s
∗2
Inverter
rated
current
3 Hz
8
0.5 s
4%
∗3
2%
∗4
0.5 Hz
5 Hz
0.5 s
0
120 Hz
8888
50 Hz
150%
9999
9999
0
0
9999
9999
9999
9999
9999
9999
0
10%
6 Hz
9999
21