Mitsubishi Electric FREQROL-CS80 Manual page 24

Hide thumbs Also See for FREQROL-CS80:
Table of Contents

Advertisement

Function
Pr.
592
A300
593
A301
594
A302
595
A303
596
A304
597
A305
598
H105
611
F003
631
H104
660
G130
661
G131
662
G132
665
G125
774
M101
775
M102
776
M103
778
T054
872
H201
∗5
882
G120
8
883
G121
885
G123
886
G124
C2
T200
(902)
∗8
C3
T201
(902)
∗8
125
T202
(903)
∗8
C4
T203
(903)
∗8
C5
T400
(904)
∗8
C6
T401
(904)
∗8
126
T402
(905)
∗8
C7
T403
(905)
∗8
990
E104
991
E105
PrCL
ALLC
Er.CL
Pr.CH
Pr.MD
∗1
Differs according to the capacity.
6%: FR-CS84-022 or lower, FR-CS82S-042 or lower
4%: FR-CS84-036 to FR-CS84-080, FR-CS82S-070, FR-CS82S-100
3%: FR-CS84-120 and FR-CS84-160
2%: FR-CS84-230 or higher
∗2
Differs according to the capacity.
5 s: FR-CS84-080 or lower
10 s: FR-CS84-120 and FR-CS84-160, FR-CS82S-042 or lower
15 s: FR-CS84-230 or higher
∗3
The Initial value for the FR-CS84-160 or lower and the FR-CS82S-100 or lower.
∗4
The initial value for the FR-CS84-230 or higher.
∗5
Available only for the three-phase power input model.
∗6
24
The value for the 200 V class.
∗7
The value for the 400 V class.
∗8
The parameter number in parentheses is the one used (displayed) on the LCD operation panel and the parameter unit.
Pr.
Name
group
Traverse function selection
Maximum amplitude amount
Amplitude compensation amount during
deceleration
Amplitude compensation amount during
acceleration
Amplitude acceleration time
Amplitude deceleration time
Undervoltage detection enable/disable
selection
Acceleration time at a restart
Inverter output fault detection enable/disable
selection
Increased magnetic excitation deceleration
operation selection
Magnetic excitation increase rate
Increased magnetic excitation current level
Regeneration avoidance frequency gain
Operation panel monitor selection 1
Operation panel monitor selection 2
Operation panel monitor selection 3
4 mA input check filter
Input phase loss protection selection
Regeneration avoidance operation selection
Regeneration avoidance operation level
Regeneration avoidance compensation
frequency limit value
Regeneration avoidance voltage gain
Terminal 2 frequency setting bias frequency
Terminal 2 frequency setting bias
Terminal 2 frequency setting gain frequency
Terminal 2 frequency setting gain
Terminal 4 frequency setting bias frequency
Terminal 4 frequency setting bias
Terminal 4 frequency setting gain frequency
Terminal 4 frequency setting gain
PU buzzer control
PU contrast adjustment
Parameter clear
All parameter clear
Fault history clear
Initial value change list
Group parameter setting
Minimum
Setting range
setting
increment
0 to 2
1
0 to 25%
0.1%
0 to 50%
0.1%
0 to 50%
0.1%
0.1 to 3600 s
0.1 s
0.1 to 3600 s
0.1 s
0, 1
1
0 to 3600 s, 9999
0.1 s
0, 1
1
0, 1
1
0 to 40%, 9999
0.1%
0 to 200%
0.1%
0 to 200%
0.1%
1
1 to 3, 5, 8, 10, 14, 20,
1
23 to 25, 52 to 55, 61, 62,
100
1
0 to 10 s
0.01 s
0, 1
1
0 to 2
1
300 to 800 V
0.1 V
0 to 10 Hz, 9999
0.01 Hz
0 to 200%
0.1%
0 to 400 Hz
0.01 Hz
0 to 300%
0.1%
0 to 400 Hz
0.01 Hz
0 to 300%
0.1%
0 to 400 Hz
0.01 Hz
0 to 300%
0.1%
0 to 400 Hz
0.01 Hz
0 to 300%
0.1%
0, 1
1
0 to 63
1
(0), 1
1
(0), 1
1
(0), 1
1
1
(0), 1, 2
1
Initial
Customer
value
setting
0
10%
10%
10%
5 s
5 s
1
9999
1
0
9999
100%
100%
1
2
3
0 s
1
0
400 VDC
∗6
780 VDC
∗7
6 Hz
100%
0 Hz
0%
50 Hz
100%
0 Hz
20%
50 Hz
100%
1
58
0
0
0
0
0