External Device Settings
To configure communication settings, use the MENU, DATA/ENTER, Up, Down, or Shift/RESET key on the
digital operator located on the front of the inverter. Refer to your External Device manual for details.
1
Press the MENU key to select [Programming].
2
Press the DATA/ENTER key.
3
Press the Up key to display the parameter you want to set.
4
Press the DATA/ENTER key.
5
Press the Up, Down, or Shift/RESET key to display the setting value.
Parameter No.
H5-01
H5-02
H5-03
H5-04
H5-05
H5-06
H5-07
6
Press the DATA/ENTER key.
7
Reboot the External Device.
This completes the setting of the External Device.
GP-Pro EX Device/PLC Connection Manual
Settings
01
Slave address (HEX)
3
Communication speed selection
1
Communication parity selection
3
Stopping method after communication error
1
Communication error detection selection
5
Send wait time
1
RTS control ON/OFF
28
Setup Description
Inverter SIO Driver