External Device Settings
To configure communication settings, use the DSPL, DATA/ENTER, Up, or Down key on the digital operator
located on the front of the inverter. Refer to your External Device manual for details.
1
Press the DSPL key to select [PRGM].
2
Press the Up key to display the parameter you want to set.
3
Press the DATA/ENTER key.
4
Press the Up or Down key to display the setting value.
Parameter No.
n03
n04
n153
n154
n155
n156
n157
5
Press the DATA/ENTER key.
6
Reboot the External Device.
This completes the setting of the External Device.
GP-Pro EX Device/PLC Connection Manual
Settings
2
RUN Command Selection
6
Frequency Reference Selection
1
Slave Address Setting (DEC)
2
Baud Rate Selection
0
Parity Selection
10
Transmission Wait Time
0
RTS Control
22
Setup Description
Inverter SIO Driver