7 Installation Precautions

Installation must be performed by qualified service
technicians.
Work on the electrical installation must only be carried out by
authorised specialist personnel.
The load capacity and suitability of the supporting
construction of the building in which the door operator is to be
installed must be inspected and approved by an expert.
The door operator must be fully and securely attached at all
fastening points. All fastening materials must be selected
according to the nature of the supporting construction and
they must be able to withstand traction force of 900 N.
In the event of non-conformance with these
requirements, there is a risk of injury and material
damage caused by a falling operator or an uncontrolled
movement of the door.
When drilling the fastening holes, do not damage the building
structure or any electrical, water or other lines.
After lifting up the door operator to the ceiling, fasten it fully
with appropriate tools to prevent it from falling down.
Please observe appropriate industrial safety regulations and
keep children away during installation.

8 Safety devices of the Door Operator

The door operator has the following safety devices. Do
not remove them or alter their functionality.
• Automatic load switch-off during functions "OPEN" and
"CLOSE"
• Connection for light barrier / safety edge / optosensor
• Emergency lock release (see page 15 (N)

9 Safety Inspection

Checking Load Switch-off

The automatic load switch-off is a clamping and safety
mechanism that is designed to prevent accidents due to a
moving door.
Stop the door from outside with both hands at waist height.
When closing:
The door must stop automatically and reverse a little if it
comes into contact with an obstruction.
When opening:
The door must stop automatically if it comes into contact with
an obstruction.

Emergency Lock Release

Check as per the information provided on page 15 (N).

Additional Safety Devices

Check for proper functioning as per the manufacturer's
instructions.
18 / 56

10 Controls and Indicators

1
LED 1
2
LED 2
3
LED 3-6
10 POWER button
11 PROG button
12 CANC button
13 TEST button
Signals of the indicator lamps 1 to 3
3
Set force tolerance
1 + 2 Status during programming

11 Connections

4
Antenna
5+6 External switch
7-9 Light barrier

12 Installation Preparations

Please note: Check that the door is working properly
and running smoothly, and adjust if necessary. The
spring tension of the door must be set in such a way that it is
stable and can be opened and closed by hand smoothly and
without jolting.
• Standard and appropriate
- 50 cm near the fastening point at the head of the operator.
• Only install the door operator in dry garages.

13 Installation

See instructions for installation from page 9.

14 Commissioning

Once installation is complete
• connect the door to the door operator by: slowly opening
the door by hand until you hear the slide snap in.
• Connect to the mains, LED 1 (red) flashes.
• Teach in the door operator (see Chapter 15).
• Teach in the remote transmitter (see Chapter 16).
• Carry out a safety inspection (see Chapter 9).
MA120527=>2012-05
shock-proof sockets approx. 10
EasyLift 500 / Sesam 600