Service information
How to avoid equipment failures with preventive maintenance
measures
Product line
Tower pureEnergy
1. General information
Preventive maintenance measures are defined as the reg-
ular performance of equipment maintenance practices in
order to avoid future equipment problems.
An important first step is to learn how to identify possible
causes of equipment failure. KBL provides managers and
service technicians with the knowledge to identify causes
that have been known to cause malfunctions.
KBL encourages managers to establish an effective pre-
ventive maintenance program and to use the checklist
on the last page to verify the maintenance status of their
tanning device.
In case of questions, contact our service representative.
1.1
Definitions
- Qualified, trained and authorized service technician
Qualified staff who have been trained and autho-
rized by the manufacturer for assembly and main-
tenance work with specific devices.
- Staff
People who are responsible for the operation,
cleaning and disinfection as well as for the general
maintenance work and instruction of the user on
how to operate the tanning devices.
- Studio operator
People who provide tanning devices to users on a
commercial basis. The studio operator is trained
to operate and maintain the tanning device. He is
responsible for the proper operation of the tanning
device as well as for compliance with the mainte-
nance intervals.
- User
A person who uses the tanning device.
08/2017

Advertisement

loading

Summary of Contents for KBL pureEnergy T230 W

  • Page 1 An important first step is to learn how to identify possible causes of equipment failure. KBL provides managers and service technicians with the knowledge to identify causes that have been known to cause malfunctions.
  • Page 2: Obligations Of The Studio Operator

    • Please note that the tanning device must be prevention regulations. He must ensure that his staff inspected regularly by an authorized KBL has understood and observes these instructions. representative every 12 months from the date...
  • Page 3: Maintenance Intervals

    Component Activity Replace Additional maintenance intervals Inspect and replace Electronic as necessary Inspect the tanning device by a KBL autho- starters Yearly rized representative every 12 months from Replace maintenance date of the last inspection. Inspect and replace If the tanning device is in use for longer than...
  • Page 4: Current Versions

    Item no.: ranty! If not, please contact: • Maintain the minimum distances from rear wall KBL AG and side walls: Ringstraße 24-26 · 56307 Dernbach · Germany fon +49 (0) 26 89.94 26-0 · fax 94 26-66 e-mail: customerservice@kbl.de...
  • Page 5 2086 R 230W -> TE-time 7 minutes KBL item no.: 3230074855 megaLine 2082 R 230W -> TE-time 10 minutes KBL item no.: 3230075060 - The use of any other UV lamps voids the operating license! Installation record form filled out...
  • Page 6 200-250 Vac 50/60 Hz (-5 C to +80 • Check for neutrality • Ground and short-circuit KBL item no.: 3200304120 • Cover or shield any adjacent live parts or compo- nents - The use of unsuitable starters can lead to electri-...
  • Page 7 Test the conductors with a pincer for their tight fit. Use only OEM spare parts: Electronicon E12.E43-404500 MKP 45 F ±5% - 280V 50/60Hz KBL item no.: 3200285000 KBL approved alternative: Ducati - Series 4.16.31.96.93 MKP 45 F ±5% - 280V 50/60Hz...
  • Page 8 08/2017 4. Important positions: Connections at the top of the rear wall - left and right Positions from outside Back panel Attention Professional replacement of plug/socket is conducted from inside the tanning device. Under no circumstances pull the wire harness out of the socket from outside! This may cause a reduction of the contact quality and could lead to electrical overstress.
  • Page 9 08/2017 Check positions from outside Signs of electrical overstress - EOS Check all connections externally for Check the plugs on signs of electrical overstress! signs indicating electrical • Discoloration • Deformations overstress. • Melting Check the connector and socket inte- •...
  • Page 10 08/2017 Very important assembly information WAGO connector Adels connector WAGO male connector WAGO female connector Adels male connector Adels female connector Never use the connectors without tention relief housing. Attention Attention Improper installation Improper installation with with risk of electrical risk of electrical shock! shock!
  • Page 11 08/2017 Check positions from inside Perfect condition • Lay the individual wires and the cable harness as shown in the figure. • Use sufficient cable ties and position them as shown in the figure. • Ensure good contact. • Route the wires min. 1.2 inches vertically out of the connector plug.
  • Page 12 08/2017 Bad or no contact Missing cable ties Missing cable ties and messy cable routing...
  • Page 13 Missing cable ties and messy cable routing After completion of the work check the position of the plugs on the back of the tanning device Installation record form filled out Date checked: Checked by: To finish the process, please send the completed checklist to e-mail: customerservice@kbl.de...