Dmx Set Up - ADJ HYDRO BEAM X2 User Instructions

Table of Contents

Advertisement

Hydro Beam X2

DMX Set Up

DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of
commnuication between intelligent fixtures and controllers. A DMX controller sends DMX data
instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to
fixture via the DATA "IN" and DATA "OUT" XLR terminals located on all DMX fixtures (most controllers
only have a DATA "OUT" terminal).
DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked
together and operate from a single controller, as long as all fixtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the
shortest cable path possible. The order in which fixtures are connected in a DMX line does not
influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed
anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that
unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The Hydro BeamX2 can be controlled
via DMX-512 protocol. Your unit and your DMX controller requires a 5-pin XLR connector for data input
and data output. We recommend Accu-Cable DMX cables. If you are making your own cables, be sure
to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting
stores). Your cables should be made with a male and female XLR connector on either end of the cable.
Also remember that DMX cable must be daisy chained and cannot be split.
Special Note: Line Termination. When longer runs of cable are used, you may need to use a
terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor
which is con- nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit
is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using
a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE
FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED AND ONLY IP65
RATED POWER AND DATE CABLES MUST BE USED.
ADJ Products, LLC -
www.adj.com
- Hydro Beam X2 User Manual
Page
27

Hide quick links: