The manual contains information about purpose, technical details, operating principle, design, and installation of the TwinFresh Elite 160/200 (Pro) (L055/07/1) unit and all its modifications. Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.
Page 3
TwinFresh Elite 160/200 (Pro) (L055/07/1) Ensure that the unit is switched off from the supply mains before removing the guard. Do not attach the product to the support using glue or adhesives. Use only the fastening method specified in the “User’s manual”.
Page 4
TwinFresh Elite 160/200 (Pro) (L055/07/1) WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: USE THIS UNIT ONLY IN THE MANNER INTENDED BY THE MANUFACTURER. IF YOU HAVE QUESTIONS,CONTACT THE MANUFACTURER. BEFORE SERVICING OR CLEANING UNIT, SWITCH POWER OFF AT SERVICE PANEL AND LOCK THE SERVICE DISCONNECTING MEANS TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.
TwinFresh Elite 160/200 (Pro) (L055/07/1) DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS! MAKE SURE THE UNIT IS DISCONNECTED FROM POWER MAINS BEFORE REMOVING THE PROTECTION. FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND TROUBLE-FREE OPERATION OF THE UNIT USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE UNIT,...
TwinFresh Elite 160/200 (Pro) (L055/07/1) TECHNICAL DATA The temperature in the room where the indoor unit of the ventilator is installed must be in the range from +41 °F to +104 °F (from +5 °C to +40 °C) and relative humidity up to 70 % (without humidity condensation). Provide fresh air through the windows.
TwinFresh Elite 160/200 (Pro) (L055/07/1) DESIGN AND OPERATING PRINCIPLE The product consists of an operating module with the indoor unit and external coating. The operating module contains fans, the heat exchanger, heaters, supply and extract air ducts. Heat exchanger is used to transfer heat energy between the air flows.
TwinFresh Elite 160/200 (Pro) (L055/07/1) MOUNTING AND SET-UP READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT WHEN THE PRODUCT IS INSTALLED IN BUILDINGS, WHERE WIND OVERLOAD IS POSSIBLE, IN PREMISES WITH PASSIVE VENTILATION, FIREPLACES OR PRE-INSTALLED VENTILATION UNITS (EXTRACT FANS, KITCHEN HOOD ETC.) SUPPLY AND EXTRACT AIR IMBALANCE IS POSSIBLE IT MAY CAUSE DRAFTS AND DESTABILIZE TEMPERATURE IN WINTER SEASON.
Page 10
TwinFresh Elite 160/200 (Pro) (L055/07/1) When choosing the location of the product in resting and sleeping areas, keep in mind that the product will act as an additional source of noise. Keep in mind that during the cold season, the supply air temperature from the product will be lower than the ambient temperature.
Page 11
In cases where the installation site is accessible from the outer side of the wall, a compensation pad or a metal seal can be used, which must be purchased separately. The figure below shows a set of compensation pads and an example of their use for mounting the TwinFresh Elite 160/200 (Pro) product in a wall with a thickness of less than (400 mm).
Page 12
TwinFresh Elite 160/200 (Pro) (L055/07/1) Algorithm for shortening TwinFresh Elite 160/200 (Pro) (L055/07/1) units If the wall thickness is equal to the value L of your product, you may start with the step 1 of the unit mounting instruction. If the L value of your product is greater than the wall thickness, it may be shortened before installation.
Page 13
TwinFresh Elite 160/200 (Pro) (L055/07/1) To insulate the heater and make the cut airtight, use the insulating tube with an adhesive layer (included in the delivery set). Put on a 1 3/16" (30 mm) long section of it. Fit it using an industrial dryer.
Page 14
TwinFresh Elite 160/200 (Pro) (L055/07/1) Unit installation 1. Prepare a round core hole in the outer wall 6 3/4" (172 mm) in diameter for TwinFresh Elite 160 models and 8 3⁄8" (212 mm) in diameter for TwinFresh Elite 200 models.
Page 15
TwinFresh Elite 160/200 (Pro) (L055/07/1) 5. Put the mounting template on the wall. Align it using the level. Afterward, mark the openings to insert dowels from the mounting kit and drill the holes of required depth. When wiring, mark the cable outlet site (pos. 1). Pull the power cord through to the marked site.
TwinFresh Elite 160/200 (Pro) (L055/07/1) CONNECTION TO POWER MAINS The unit is rated for connection to power mains with the parameters specified in the “Technical data” section. The unit must be connected using the power cord with a plug pre-installed at the factory, or fixed wiring.
TwinFresh Elite 160/200 (Pro) (L055/07/1) UNIT CONTROL The product can be controlled using the remote control, a smartphone app via Wi-Fi and the Google Assistant. Before turning on the unit, open the rotating dampers on the indoor part of the unit.
Page 18
TwinFresh Elite 160/200 (Pro) (L055/07/1) Connecting your smartphone device to the product You can download the app by following the link to the App Store or Play Market, or by using QR codes. Vents Home – App Store Vents Home – Play Market...
Page 19
TwinFresh Elite 160/200 (Pro) (L055/07/1) The main modes, functions, settings available in the smartphone application are as follows: On/Off. Turning the product on or off. Speed switch: 1, 2, 3 Selecting the appropriate fans speed. It is controlled using the buttons on the remote control or in the smartphone app.
Page 20
TwinFresh Elite 160/200 (Pro) (L055/07/1) Heat exchanger frost protection The unit has an algorithm to protect the heat exchanger from frost in winter season. According to the algorithm, if heat exchanger frost danger is detected, gradual supply fan speed decrease (until it stops), gradual extract fan speed increase, or automatic heater power-on may be initiated.
TwinFresh Elite 160/200 (Pro) (L055/07/1) TECHNICAL MAINTENANCE DISCONNECT THE PRODUCT FROM THE POWER SUPPLY BEFORE PERFORMING ANY MAINTENANCE WORK Maintenance of the ventilator means regular dusting of the ventilator surfaces and cleaning and replacing the filters. To access the filters, remove the decorative panels from the operating module.
TwinFresh Elite 160/200 (Pro) (L055/07/1) If necessary, the remote control battery may be replaced. No response of the unit for pressing the remote control buttons indicates the need to replace the battery. The battery type is CR2025. Remove the holder with the battery from the bottom part of the remote control.
TwinFresh Elite 160/200 (Pro) (L055/07/1) MANUFACTURER’S WARRANTY Production meets standard operating requirements in the USA and Canada. Vents US warrants to the original purchaser of the unit that it will be free from defects in materials or workmanship for a period of 24 months from the date of original purchase.
TwinFresh Elite 160/200 (Pro) (L055/07/1) CERTIFICATE OF ACCEPTANCE Unit Type Single Room Heat Recovery Ventilation Unit Model Serial Number Manufacture Date Quality Inspector’s Stamp SELLER INFORMATION Seller Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted.