Appendix
Appendix
A Operator level – overview
Setting level
Heating installation
Pressure in the heating in-
stallation
Heating flow temperature
Hot water generation
Hot water temperature
Eco hot water temperature
B Troubleshooting
Fault
Product does not
The gas isolator cock installed on-site
start up:
and/or the gas isolator cock on the
product is closed.
– No hot water
The cold water stop cock is closed.
– Heating does
The power supply in the building is dis-
not heat up
connected.
The product is switched off.
The heating flow temperature or hot
water temperature has been set too
low.
The system pressure is insufficient.
Low water pressure in the heating in-
stallation (fault code: F.22).
The system pressure is too high.
14
Values
Unit
Min.
Max.
Current value
bar
1
1.5
℃
Current value
10
Preset
in the
system
Current value
℃
35
60
Current value
℃
35
50
Cause
Operating instructions Easicom 3 0020239561_01
Increment, select
0.1
1
1
1
Measure
Open both gas isolator cocks.
Open the cold water stop cock.
Check the fuse in the build-
ing. The product automatically
switches on after the power
supply is restored.
Switch on the product (→ "Switch-
ing on the product" section).
Set the heating flow temperat-
ure and hot water temperature (→
"Setting the heating flow temper-
ature" section/→ "Setting the hot
water temperature" section).
Fill the heating installation (→
"Filling the heating installation"
section).
If the pressure drops frequently,
contact your competent person
about this.
Purge a radiator in order to re-
duce the pressure in the heating
installation, or contact your com-
petent person about this.
Default set-
ting
60
55
Need help?
Do you have a question about the Easicom 3 24c and is the answer not in the manual?
Questions and answers
How does easicom 3 25r know what heating temperature is required?
The Glow-worm Easicom 3 24c determines the required heating temperature by allowing the user to set the heating flow temperature using the control buttons. The display shows the current heating flow temperature, and the user can adjust it by increasing or decreasing the selected setting. The system also considers the filling pressure in the heating installation and the operating mode, which are displayed on the basic display.
This answer is automatically generated