3.9
P.C.B. PROGRAMMING
The water heater is set up for possible programming of several op-
eration parameters. By modifying these parameters as described
below, the system can be adapted according to specific needs.
To access the programming phase, press the "MENU" button (2)
until the "Password" menu appears. Enter the password, modify
the numerical values using the "central heating regulation" but-
tons (5) and confirm with the "OK" button (1).
Id
Parameter
Parameter
A 03
Minimum speed
Maximum fixed
A 04
speed
Outdoor unit
A 11
model
A 12
System vent
Number of
A 13
zones
Zone 2 max
A 14
temperature
Zone 3 max
A 15
temperature
Zone 1 humidity
A 16
sensor
Description
Defines the minimum operating speed of the system circula-
tor pump
Defines the maximum operating speed of the system
circulator pump
Establishes the outdoor unit model paired with the indoor
unit.
If set to OFF, only the integrated generators are activated.
Enables the automatic vent function.
This function activates as soon as the unit is powered.
Defines the number of zones in the heating system
Defines the maximum temperature acceptable by zone 2
Defines the maximum temperature acceptable by zone 3
Defines the type of control on zone 1 humidity
Once you have accessed programming, you can scroll through the
parameters in the "System" menu.
Using the "central heating regulation" button, select the parame-
ter and edit the value.
To save the parameter change, press the "OK" button.
Wait for 1 minute or press the "ESC" button (3) to exit program-
ming mode.
Range
0 ÷ 100 %
45 ÷ 100 %
OFF - 4 - 6 - 9
OFF - ON
1 - 3
20 ÷ 80 °C
20 ÷ 80 °C
SE =
Humidity
temp. Sensor
ST =
Humidistat
RP - Remote
panel
RPH =
Remote panel
with humidis-
tat
Value
Default
value
100
100
6
ON
1
45
45
ST
57