Installing The Blower - Napoleon High Definition Series Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

optional blower installation
EN

10.2 installing the blower

Open the blower kit and remove the blower, you won't need the supplied wire harness. Connect flag
A.
connectors from the power cord supplied with the appliance to the male posts on the blower. Plug the
cord into the female pigtail attached to X-10 of the control board.
Reverse procedure to re-assemble.
B.
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must
be electrically connected and grounded in accordance with local codes.
In the absence of local codes, use the current CSA C22.1 Canadian
electrical code in Canada or the ANSI / NFPA 70 national electrical code
in the United States.
Drywall dust will penetrate into the blower bearings, causing
irreparable damage. Care must be taken to prevent drywall dust from
coming into contact with the blower or its compartment. Any damage
resulting from this condition is not covered by the warranty policy.
To safely install the fan, turn off the electricity first.
Slide the vibration reducing pad (A) into the clip (C) and up against the threaded
stud (B) at the other end. The blower must be able to be positioned entirely onto
the pad.
36
W415-1596 / B / 10.12.18
BLOWER
GASKET
B
A
MALE POSTS
BLOWER
BLOWER CORD
(SUPPLIED WITH
APPLIANCE)
C