Finish Framing - Napoleon High Definition Series Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

E R
A joint compound that is resilient to heat and cracking should be used when taping and mudding
seams.
Non-combustible Material Definitions
Material which will not ignite and burn. Materials consisting entirely of steel, iron, brick, tile, concrete, slate, glass
or plasters, or any combination thereof are suitable.
Materials that are reported as passing ASTM E 136, Standard Test Method for Behaviour of Materials in a
Vertical Tube Furnace at 750°C and UL763 shall be considered non-combustible materials.
COMBUSTIBLE
MATERIAL
2" (51mm)
40 ¼"
MIN.
(1022mm)
NON-COMBUSTIBLE
MATERIAL SUCH AS TILE,
MARBLE, GRANITE, ETC.
9 ½"
(241mm)
2" (51mm)
MIN.

finish framing

47 ½"
(1206mm)
W415-1596 / B / 10.12.18