INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACES.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions
are not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
HDX40NT-1

NATURAL GAS

HDX40PT-1
WARNING
!
PROPANE
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
C E R T I F I E D
1.36A
W415-1089 / 08.08.12
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon HDX40NT-1

  • Page 1: Natural Gas

    TOUCH GLASS. C E R T I F I E D Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com 1.36A...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION VENTING VENTING LENGTHS AND COMPONENTS TYPICAL VENT INSTALLATIONS SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION 3.3.2 CORNER TERMINATION VENT TERMINAL CLEARANCES VENT APPLICATION FLOW CHART DEFINITIONS ELBOW VENT LENGTH VALUES HORIZONTAL TERMINATION VERTICAL TERMINATION INSTALLATION...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Venting, see “VENTING” Mantel, see “MINI- section. MUM MANTEL CLEARANCES” section. Enclosures, see the section “MINIMUM CLEARANCES TO COMBUSTIBLE ENCLOSURES” section for drywall (or other combustible material). Enclosures, see the section “MINIMUM CLEARANCE TO COMBUSTIBLE Framing, see ENCLOSURES”...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Dimensions

    DIMENSIONS 3” 3” 39 ¼” 28” 1" 41” 38” 10 ³/ ” 33 ¾” 20” 20 ½” 2" 5" 2" 8" 40 ¼” GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 6: General Information

    Natural Propane Control Input Input 4.5” w.c. 11.0” w.c. Minimum Inlet BTU/h BTU/h 7.0” w.c. 13.0” w.c. Maximum Inlet HDX40NT-1 IPI Hi/Lo 40,000 26,000 3.5” w.c. 10.0” w.c. Manifold Pressure HDX40PT-1 Prop* IPI Hi/Lo 36,000 26,000 EFFICIENCY RATINGS IPI - Intermittent Pilot Ignition System...
  • Page 7: Rating Plate Information

    MANUEL D'INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES. WOLF STEEL LTD. SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS. S. S. 24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 4Y8 CANADA 24 NAPOLEON RO 24 NAPO SE RÉFÉRER AU MANUEL D'INSTALLATION DU PROPRIÉTAIRE POUR LES LONGUEURS...
  • Page 8: Venting

    3.0 VENTING WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3 FEET FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES.
  • Page 9: Typical Vent Installations

    For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a minimum. The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged. Rigid and fl...
  • Page 10: Special Vent Installations

    SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” above grade. The maximum allowable vent length is 10’ for a 12”...
  • Page 11: Vent Terminal Clearances

    VENT TERMINAL CLEARANCES COVERED BALCONY APPLICATIONS ††* = 3 feet = 2 x ACTUAL INSTALLATIONS feet CANADA U.S.A. 12” 12” Clearance above grade, veranda porch, deck or balcony. 12” Δ 9” Δ Clearance to windows or doors that open. 12” * 12”...
  • Page 12: Vent Application Flow Chart

    VENT APPLICATION FLOW CHART Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run Horizontal run + Horizontal run +...
  • Page 13: Horizontal Termination

    HORIZONTAL TERMINATION ) < (V See graph to determine the required vertical Simple venting confi guration (only one 90° elbow) rise V for the required horizontal run H REQUIRED VERTICAL RISE IN FEET V 12.5 17.5 HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H...
  • Page 14 ) > (V Simple venting configuration (only one 90° elbow) See graph to determine the required vertical rise V for the required horizontal run H 147” REQUIRED VERTICAL RISE IN INCHES V 57” 24” 2’ 19.5’ 12.5’ HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V...
  • Page 15: Vertical Termination

    VERTICAL TERMINATION ) < (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V For vent configurations requiring one or more 90°...
  • Page 16 ) > (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V For vent configurations requiring more than two 90°...
  • Page 17: Installation

    4.0 INSTALLATION WARNING FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY. ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED RTV HIGH TEMP SILICONE SEALANT W573-0002 (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC W573-0007 (NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR WHICH MUST BE SEALED USING MILL PAC.
  • Page 18: Horizontal Installation

    4.1.1 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal VENT location, cut and frame a hole in the exterior wall as...
  • Page 19: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS WARNING DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER FLEX PIPE.
  • Page 20: Vertical Air Terminal Installation

    4.2.2 VERTICAL AIR TERMINAL INSTALLATION WARNING MAINTAIN A MINIMUM 2” SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 21: Mobile Home

    MOBILE HOME This appliance is also certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home (U.S. only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada.
  • Page 22: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 23 It is best to frame your appliance after it is positioned and the vent system is installed. Frame to local building codes. It is not necessary to install a hearth extension with this appliance. When roughing in the appliance, raise the appliance to accommodate for the thickness of the fi nished fl oor materials, i.e.
  • Page 24: Minimum Clearance To Combustibles

    MINIMUM CLEARANCE TO COMBUSTIBLES COMBUSTIBLE FRAMING: Sides, back, bottom of the 0” to stand-offs appliance COMBUSTIBLE FINISHING: Sides 2” to front edge of the appliance Enclosure Top 84” from the bottom of the appliance Recessed Depth 20 1/4” Sides of the vent pipe 2”* Bottom of the vent pipe 1”...
  • Page 25: Minimum Clearance To Combustible Enclosures

    MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES NON-COMBUSTIBLE COMBUSTIBLE BRICK 18” 0” IF NON-COMBUSTIBLE 2” FINISHING IS USED SUCH AS BRICK AND STONE WOOD HEADER 4” 46” 1” 84” 9 1/2” 62” NON- MINIMUM COMBUSTIBLE PLUS MATERIAL RISE* FRONT HOOD 38” 1” For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
  • Page 26 COMBUSTIBLE MATERIAL NON-COMBUSTIBLE MATERIAL SUCH AS TILE, MARBLE, GRANITE, ETC. 47 ½” 2” MIN. 40 ¼” 2” MIN. A joint compound that is resilient to heat and cracking should be used when taping and mudding seams. Non-combustible Material Defi nitions Material which will not ignite and burn.
  • Page 27: Alcove Installation

    ALCOVE INSTALLATION RECESS OR ALCOVE AREA ENCLOSURE AREA APPLIANCE NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum clearances to combustibles are maintained. Non-combustible material can be used, provided the minimum clearances to combustible materials are applied. The minimum enclosure volume must be increased by no less than the volume of the recess.
  • Page 28: Minimum Mantel Clearances

    MINIMUM MANTEL CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 29: Finishing

    6.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED. DO NOT STRIKE, SLAM OR SCRATCH GLASS.
  • Page 30: Log Placement

    LOG PLACEMENT WARNING LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT CHANGE OR MODIFY FROM THE PROPER LOG POSITION, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED IGNITION MAY OCCUR. THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE. The individual logs can be easily identifi...
  • Page 31: Glowing Ember Placement

    Align the holes in the bottom of the right log (W135-0447) with the pins in the rear and front right log. Align the holes in the bottom of the middle log (W135-0445) with the pins in the front left and right logs. Align the hole in the bottom of the left log (W135-0446) with the pin in the rear log.
  • Page 32: Optional Rock Placement

    OPTIONAL ROCK PLACEMENT WARNING REAL ROCKS MUST NOT BE USED IN THIS APPLIANCE. HEAT WILL CAUSE THEM TO EXPLODE. LOG SUPPORT ROCK SUPPORT Notched Rock FRONT BURNER PORTS AIR VENTS Before beginning with the installation, remove the door and all burner media from the unit. eg. logs, charcoal etc.
  • Page 33: Logo Placement

    LOGO PLACEMENT 1/2” Remove the backing of the logo supplied and place on the glass viewing door or bottom access panel as illustrated. 1/2” 1” 1/2” 7.0 OPTIONAL BLOWER INSTALLATION WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.
  • Page 34: Installing The Blower

    INSTALLING THE BLOWER Open the blower kit and remove the blower, you won’t need the supplied wire harness. Connect fl ag connectors from the power cord supplied with the appliance to the male posts on the blower. Plug the cord into the female pigtail attached to X-10 of the control board. Reverse procedure to re-assemble.
  • Page 35: Wiring Diagram / Electrical Information

    8.0 WIRING DIAGRAM / ELECTRICAL INFORMATION WARNING DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE ELECTRICAL CIRCUIT. RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE APPLIANCE WALL SWITCH.
  • Page 36: Wiring Diagram (Ifc Module)

    WIRING DIAGRAM (IFC MODULE) WARNING DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH. A wall switch must be installed in a convenient location for the burner operation. The recommended maximum lead length depends on the wire size: WIRE SIZE MAX.
  • Page 37: Operation

    9.0 OPERATION WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 38: General Transmitter Layout

    GENERAL TRANSMITTER LAYOUT Key Lock Low battery alarm Transmission Room Temperature CPI mode Flame ON Night Light Blower INITIALIZING THE TRANSMITTER FOR THE FIRST TIME Power the receiver. Press the reset button to begin the programming process. The receiver will BEEP 3 times to indicate that it is ready to synchronize with a transmitter.
  • Page 39: Temperature Display

    TEMPERATURE DISPLAY With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same °F °C time to change from degrees F to C. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of the Room Temperature display.
  • Page 40: Night Light Dimmer Control

    NIGHT LIGHT DIMMER CONTROL The auxiliary function controls the Night Light with °F °F dimmable control. Use the Mode Key to guide you to the Night Light icon. The intensity of the output can be adjusted through 6 levels. Use the UP/DOWN arrow keys to adjust the output level.
  • Page 41: Low Battery / Manual Bypass

    LOW BATTERY / MANUAL BYPASS The life span of the remote batteries depends on various factors: quality of the °F batteries, the number of ignitions, the number of charges to the room thermostat set point, etc. When the transmitter batteries are low, a Battery Icon will appear on the LCD display before all battery power is lost.
  • Page 42: Venturi Adjustment

    10.3 VENTURI ADJUSTMENT This appliance has an air shutter that has been factory set open according to the chart below: VENTURI BURNER Regardless of venturi orientation, closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
  • Page 43: Maintenance

    11.0 MAINTENANCE MAINTENANCE MAINTENANCE WARNING MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 44: Door Glass Replacement

    11.2 DOOR GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 45: Replacement Parts

    GLASS C/W GASKET W010-2280 BLACK DOOR C/W GLASS W456-0031 ORIFICE NATURAL GAS W456-0051 ORIFICE PROPANE GAS W010-1800 FIRESTOP SPACER W385-0334 NAPOLEON® LOGO W750-0193 20 FT WIRE W361-0016 GLOWING EMBERS W290-0140 GAS LINE ACCESS GASKET W290-0139 BURNER TRAIN GASKET W010-2313 ASSY, REPLACEMENT BURNER...
  • Page 46 ACCESSORIES REF PART NO. DESCRIPTION W573-0007 10.3 OZ TUBE HIGH TEMP SEALANT MILPAC GZ550-1KT BLOWER KIT W660-0026 PROGRAMMABLE TIMER GA-566 HOT AIR KIT GA-72 HOT AIR EXHAUST KIT GA-70 EXTENSION KIT 5 FT PAINT, BLACK-13 OZ W175-0166 5” COUPLER W175-0002 8”...
  • Page 47 ROOF TERMINAL KITS REF PART NO. DESCRIPTION GD-410 1/12 TO 7/12 PITCH GD-411 8/12 TO 12/12 PITCH GD-412 FLAT ROOF W490-0074 5/8 INNER/OUTER SLEEVE W670-0007 5/8 TERMINAL W170-0086 STORM COLLAR W010-0453 ROOF SUPPORT W263-0066 ROOF FLASHING 1/12 TO 7/12 PITCH W263-0055 ROOF FLASHING 8/12 TO 12/12 PITCH W263-0065...
  • Page 48: Troubleshooting

    13.0 TROUBLESHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 49 SYMPTOM PROBLEM TEST SOLUTION Exhaust fumes Appliance is spilling. Check door seal. smelled in room, Check for exhaust damage. headaches. Check that venting is installed correctly. Room is in negative pressure; increase fresh air supply. Pilot will not light. Wiring. Verify the wire for the sensor and the wire for the ignitor Makes noise with are connected to the correct terminals (not reverse) on...
  • Page 50 SYMPTOM PROBLEM TEST SOLUTION Pilot sparks but Gas supply. Verify that the incoming gas line ball valve is “Open”. will not light. Verify that the inlet pressure reading is within acceptable limits, inlet pressures must not exceed 14” W.C. Module is not grounded. Verify the value and pilot assemblies are properly grounded to the metal chassis of the fi...
  • Page 51: Warranty

    All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON®...
  • Page 52 W415-1089 / 08.08.12...