Specification Summary - Rinnai HJ Cooper LCUS00934010 Owner And Installer Manual

Low pressure indoor copper tanks
Table of Contents

Advertisement

Specification summary

Low pressure copper undersink
Suitability
Indoor installations
Low pressure systems
Domestic and commercial heating applications
Top plumbing connections
Not suitable as a pool or spa heater.
Hard or aggressive water will need to be treated in
order to use this product, please test before use.
Construction
High grade copper inner cylinder
Galvanised steel outer casing
CFC-free polyurethane foam insulation
Operating pressures
Maximum inlet pressure
Maximum working pressure
Inlet
Outlet
Ø A
Connections
Refer drawing below.
Element
Low watt density nickel plated cop-
per, 1.25 " BSP boss.
Themostat
7 " Cotherm probe 20 A over-temperature
thermostat, manually resettable at 85 °C.
Weights (empty/full)
= 76 kPa
= 76 kPa
Tank
Tank code
size
9 L
LCUS00934010
14 L
LCUSO1434010
22 L
LCUS02234010
44 L
LCUS04444515
½ " BSP male (9 L, 14 L, 22 L)
¾ " BSP male (44 L)
9L:
7/16 kg
14 L:
8/22 kg
22 L:
9/31 kg
44 L:
11/55 kg
A
B
(mm)
(mm)
(mm)
Ø 340
305
120
Ø 340
410
120
Ø 340
575
120
Ø 445
585
170
Low pressure indoor copper owner and installer guide: 20733-C 03-13 | 7
C
Element rating
1 kW
1 kW
1 kW
1.5 kW

Advertisement

Table of Contents
loading

Table of Contents