Installation; Demand Rapid Specification Summary - Rinnai Demand Rapid DD1200E315N Owner And Installer Manual

Rapid recovery storage system
Table of Contents

Advertisement

Installation

Installation, servicing and repair shall be carried out only by
authorised personnel.
Supplied with the system:
Pump
Controller
UV pipe resistant insulation 15-18 mm
TPR valve(s)

Demand Rapid specification summary

Input
Output
Connections
Ingress protection
Weights
Description
A complete storage hot water system (top down heating) made up
of a Rinnai INFINITY commercial continuous flow gas water heater
(external or internal unit), a pump, a thermostat and controller, and a
315 L Demand Duo cylinder.
Suitability
For smaller commercial or larger residential applications where a
large quantity of hot water is required quickly, but there is recovery
time available before next use. For example filling a machine or spa
bath.
Hard or aggressive water will need to be treated in order to use this
system, if in doubt please test before use.
Not suitable as a pool or spa heater.
System configuration
Thermostat pump on
Thermostat pump off
INFINITY setting
Max. outlet water temp.
195-249 MJ/h
44.5-57.8 kW
Gas
DN20 ¾ " BSP male
Cold water inlet
DN32 1¼ " BSP female
Hot water outlet
DN32 1¼ " BSP female
Hot water return
DN32 1¼ " BSP female (not used)
Condensate
DN15 ½ "
TPR
DN20 ¾ " BSP female
Electricity
230 V AC GPO
IPX4
Empty
82-90 kg
Full
402-410 kg
60 °C
65 °C
75 °C
75 °C
Demand Rapid owner & installer guide 12949-B 02-19 | 9