Installation and User
Manual
REU-KBM3237FFUDHD-E
HDC 1600i Low NOx
REU-KBM3237WDHD-E
HDC 1600e Low NOx
Continuous Flow Water Heater
Important.
Read these instructions carefully before attempting installation or use of
this appliance. All work must be carried out by competent persons.

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai HDC 1600i Low NOX

  • Page 1 Installation and User Manual REU-KBM3237FFUDHD-E HDC 1600i Low NOx REU-KBM3237WDHD-E HDC 1600e Low NOx Continuous Flow Water Heater Important. Read these instructions carefully before attempting installation or use of this appliance. All work must be carried out by competent persons.
  • Page 2 Quality System Standard ISO 9001 - 2008 The Design, Development, and Manufacture of Gas Water Heating Appliances done under Rinnai’s Quality Management System is certified under the Quality Management System Standard ISO 9001. Registration Number JQ0003D Registered since: February 1994...
  • Page 3: Table Of Contents

    USERS INSTRUCTIONS FEATURES AND BENEFITS IMPORTANT INFORMATION OPERATION WITHOUT REMOTES STATUS MONITOR TEMPERATURE CONTROLS ERROR MESSAGES RECIRCULATION MODE RESTARTING THE RINNAI WATER HEATER CARING FOR THE HDC INSTALLATION INSTRUCTIONS UK INSTALLATION INSTRUCTIONS UNPACKING RINNAI WATER HEATER OPERATION MAIN COMPONENTS INSTALLATION INSTRUCTIONS...
  • Page 4: Users Instructions

    The user must not use the appliance in any way that it was not meant to be used. The user may only use the heater as detailed in the User portion of this manual. Interference with a sealed component is not permitted. In case of defect parts only use genuine Rinnai components for replacement.
  • Page 5: Features And Benefits

    Congratulations on purchasing the technologically advanced, temperature controlled, Rinnai Hot Water System. Rinnai water heaters will NEVER RUN OUT of hot water. As long as electricity,  water, and gas supplies are connected, hot water is available when hot water taps are open.
  • Page 6: Important Information

    Do make sure that the tap is turned off tightly. This approach can be extremely valuable because it requires a Do consider setting your Rinnai one time action for a long term Water Heater at a maximum reduction in risks of scalds.
  • Page 7 IMPORTANT INFORMATION Always check water temperature before Hot water may go cold without warning at use. very low water flows (less than 3 l/min). OFF! Refer to warning about hot water on page 6 for important safety information. The delivered water temperature is If freezing temperatures are expected, turn controlled automatically.
  • Page 8: Operation Without Remotes

    OPERATION WITHOUT REMOTES Rinnai HDC products have no pilot light and operate automatically as soon as water flow is sensed. The burner ignites with electronic ignition and the flame extinguishes as soon as water flowing through the appliance stops. Turn On by opening the hot water tap...
  • Page 9: Temperature Controls

    Adjustments to the operation of your hot water unit can be made with any of the Temperature Controllers. Each Temperature Controller can be individually programmed. Up to four Universal and/or Deluxe Temperature Controllers can be fitted with Rinnai water heaters. Universal Controllers allow temperature selection only and one comes as standard with some of the water heaters, Deluxe Temperature Controllers are always an optional extra.
  • Page 10 TEMPERATURE CONTROLS Remote temperature controllers provide control over the water temperature. Rinnai water heaters can be operated with 1, 2, 3, 4 or no temperature controllers. The MC-91-3A controller can be locked by pressing the Transfer button and the up-button together for 5 seconds. A beep will sound confirming that the controller is locked.
  • Page 11 The Digital Monitor will go out. If hot water taps are opened when the Rinnai HDC is off, cold water will flow from the taps. If the system is to be left off over the winter be sure to drain it down if there is a possibility of freezing temperatures.
  • Page 12 TEMPERATURE CONTROLS Using 2 or more Universal Temperature Controllers. Switching the system ON. The hot water system and all controllers can be switched ON and OFF from any controller by pressing the ON/OFF button as shown. When the system is turned ON the water temperature display will be lit.
  • Page 13 TEMPERATURE CONTROLS Do not push the ON/OFF button on the Temperature priority cannot be switched Master controller after transferring priority to another controller when the water is of temperature selection to a Secondary flowing through the water heater. controller as the system will shut down. Controller 1 Controller 2 in use...
  • Page 14: Error Messages

    ERROR MESSAGES Rinnai water heaters have the ability to check their own operation continuously. If a fault occurs, an error code will flash on the Digital Display (and on the Status Monitor). This assists with diagnosing the fault, and may enable you to overcome a problem without a service call.
  • Page 15 If this does not clear the error, try pushing the On/Off button OFF then ON again. If the Error Code still remains contact Rinnai or your nearest service agent for advice. ** Faults caused by insufficient gas/water supply or gas/water quality and installation errors are not...
  • Page 16: Recirculation Mode

    RECIRCULATION MODE The Rinnai water heater has the ability to control a recirculation pump. Two modes are available, Economy and Comfort, which recirculate the water in the plumbing system to provide hot water more quickly when a tap is opened.
  • Page 17 The Rinnai water heater should be turned on. Pump recirculation begins when the water heater is turned on. The Rinnai inlet and outlet thermistors measure the water temperature. The water heater produces hot water at the temperature setting. If the inlet thermistor detects abnormal temperature then diagnostic code 51 is generated and the pump will turn off.
  • Page 18: Restarting The Rinnai Water Heater

    If you need a recommended service engineer contact Rinnai or your supplier. The installer can refer to page 56 for main maintenance of appliance. For more detailed instructions on maintenance contact Rinnai or your supplier.
  • Page 19: Installation Instructions

    If the information in this manual is not followed exactly a fire or explosion could result. This manual must be read in its entirety before installing the appliance. If you are unsure of any point contact Rinnai or your supplier.
  • Page 20: Uk Installation Instructions

    Please be sure that you are fully aware of your obligations and responsibilities under these regulations. In case of defective parts only use genuine Rinnai components for replacement failure to do so will invalidate any warranty. Disposal Information: Under the laws and local regulations, this product must be disposed separately from house- hold waste.
  • Page 21: Unpacking Rinnai Water Heater

     A heater accessories pack is inside the carton. Remote controllers are not supplied with the Rinnai HD range of heaters because they are commercial units. If you require controllers in commercial situations they are compatible with the HD range and available from Rinnai UK or your supplier.
  • Page 22: Operation

    OPERATION Ignition Press ON/OFF Button of Remote Controller to turn on unit and the remote control- ler display and priority LED will light up. When a hot water tap is opened the Water Flow Sensor revolves and sends a pulse signal to the Printed Circuit Board (PCB).
  • Page 23: Main Components

    MAIN COMPONENTS 1. Gas Control Unit 1.1 Modulating Valve This device is used by the PCB to adjust the volume of gas to the burner in proportion to the volumetric flow rate of water in order to maintain a supply of constant temperature hot water amid changes in water flow rates and incoming temperatures.
  • Page 24: Installation Instructions

    Rinnai can not be held responsible for any consequential water damage so it may be necessary to fit a drain...
  • Page 25 See the pressure chart on page 50. Contact Rinnai or your supplier for 'gravity fed' or 'low pressure' hot water installations.
  • Page 26 INSTALLATION INSTRUCTIONS Water Connection For all closed systems (with flow and return or tank) the system must incorporate an unvented kit with the components shown below. The safety relieve valve must discharge safely into a suitable drain via a tundish. Expansion Safety Vessel...
  • Page 27 INSTALLATION INSTRUCTIONS Single unit direct flow Direct feed to the hot water outlets. Mains is fed directly into the unit. Use a strainer, but a check valve is not required. Standard domestic or small commercial set up. Used with controllers to alter the temperature at the point of use (only using hot tap) or temperature set on the dip switches for the maximum needed at any outlet, and mixed down by TMVs or manual tempering valves.
  • Page 28: Flue Requirements

    BS 5440 allow room sealed appliances to be installed in spaces and rooms, including bedrooms, without ventilation. If a Rinnai HDC internal water heater is installed in a compartment it must have the following amount of permanent ventilation.
  • Page 29 The flue must be clear of obstructions and shrubbery. Flues The Rinnai HDC Condensing water heaters internal units may only be installed with the approved Rinnai HDC flue kit provided. These instructions only apply to coaxial Rinnai Flues.
  • Page 30 FLUE REQUIREMENTS For the Rinnai HDC Condensing internal water heaters the flue system is considered part of the continuous flow water heater. The following flue type and make is approved in combination with above mentioned water heaters. M&G flu e syst em: Ubbink flue system: ...
  • Page 31 FLUE REQUIREMENTS BS5440—1 Dimen- Symbol Terminal Position sion Directly below an opening, air brick, opening windows, ect. 300mm Above an opening, air brick, opening window, ect. 300mm Horizontaly to an opening, air brick, opening window, ect. 300mm Below plastic gutters, soil pipes, drain pipes, ect. 75mm Below eaves 200mm...
  • Page 32: Condensate Disposal

    For this reason copper tube and fittings MUST NOT be used as it will corrode. Instead, Rinnai recommend plastic pipes and fittings such as Unplasticised Polyvi- nyl Chloride (UPVC) or Polyethylene (PE) which is commonly used for irrigation piping.
  • Page 33 CONDENSATE DISPOSAL...
  • Page 34: Temperature Controls

    Controller connection in parallel Cables are connected at the primary temperature controller cable. Polarity is not important when connecting Rinnai the cables. If more cable is needed any cable with similar specification to the Main Bath...
  • Page 35 TEMPERATURE CONTROLS Universal Temperature Controller - MC-91-3A 1. Determine the most suitable position for the temperature controller. 2. Drill 3 holes in the wall (Fig.1), one for the cable and two for the securing screws. Fit wall plugs if needed and ensure controller is level. 3.
  • Page 36: Ez Connect

    EZ CONNECT EZ Connect Installation The EZ Connect allows the installation of two HDC water heaters to be controlled by one remote controller without PAM valves or a MECS. This will allow temperature control through NOTE use of a single remote, while error messages will be displayed NEW FEATURE on the status monitor.
  • Page 37: Testing

    TESTING 1.Purge gas, hot water and cold water supply lines before making the final connection of the water heater. Swarf in either the gas or water supplies may cause damage. 2.Turn on gas and cold water supplies. 3.Test for water leaks and gas escapes near the unit. 4.Isolate gas and electric supply.
  • Page 38: Gas Pressure Setting

    Contact Rinnai before attempting to alter the gas pressure if you are unsure of what to do. Incorrect adjustment can void the warranty.
  • Page 39 GAS PRESSURE SETTING 10. Move switch No. 8 of SW1 to 'ON' position (Fig. 3). 11. Push the PCB board switch A for one second (Fig. 4). 12. Calibrate “forced low” combustion using switch A (up) and B (down) as required. Internal External Short flue...
  • Page 40: Dip Switch Setting

    DIP SWITCH SETTING LEGEND: Switches Explained Black Section indicates Model choiceA-1 position of dip switch. Temperature selection OFF ON OFF ON Gas TypeA-1 Gas TypeB-1 Forced Combusiton Switches Explained Model choiceA-2 Model choiceB-1 Recirculation Mode Interval time to ON of Recirculation Mode Commercial setting Gas TypeA-2...
  • Page 41 DIP SWITCH SETTING 【Temperature selection】 Temperatures - With or Without Remotes Connected 40 deg C 42 deg C 50 deg C 55 deg C Temperatures - Remotes Connected If the remote is accidentally disconnected the unit would revert to 55°C For safety reasons, move the switch no.2 of SW1 to “ON”...
  • Page 42 DIP SWITCH SETTING 【Factory Setting】 HDC 1600 i Low NOx HDC 1600 e Low NOx Off On SW1 Off On SW1 short 65°C 65°C Off On SW2 Off On SW2 short Auto Reset Auto Reset 【Recirculation Mode】 【Interval Time to ON】 【Commercial Setting】...
  • Page 43: Dimensions

    DIMENSIONS HDC1600i Low NOx...
  • Page 44 DIMENSIONS HDC1600e Low NOx...
  • Page 45: Technical Details

    TECHNICAL DETAILS Model REU-KBM3237FFUDHD-E REU-KBM3237WDHD-E Unit Installation Internal External G20 Nat Gas Press Low / High 1,2 / 7,6 1,2 / 8,1 mbar G230 Air/Propane Press Low / High 1,4 / 9,0 1,4 / 9,2 mbar G31 Propane / G30 Butane Press Low / High 1,3 / 9,2 1,3 / 8,9 mbar...
  • Page 46: Product Fiche

    TECHNICAL DETAILS PRODUCT FICHE Supplier’s Name Rinnai UK Ltd Model Name REU-KBM3237FFUDHD-E REU-KBM3237WDHD-E Declared Load Profile on Energy Label Energy Efficiency Class Water Heating Efficiency η 86.3 86.3 Annual Electricity Consumption AEC (kWh/annum) Annual Fuel Consumption AFC (GJ/annum) Second Load Profile Energy Efficiency Class Water Heating Efficiency η...
  • Page 47: Flow Chart

    FLOW CHART...
  • Page 48: Wiring Diagram

    WIRING DIAGRAM...
  • Page 49: Diagnostic Points

    DIAGNOSTIC POINTS Measurement Point Range Of Value Component Wire Colour A₁ Remote Controller BK-BK DC11-13V D₈/D₉ Thermal Fuse Below 1Ω D₂ Modulating Solenoid Valve DC2-15V / 67-81Ω D₆ Main Solenoid Valve P-BK DC11-13V / 24-28Ω D₄ Solenoid Valve 1 BL-BK DC11-13V / 36-42Ω...
  • Page 50: Water Flow Characteristics

    WATER FLOW CHARACTERISTICS...
  • Page 51: Letter Of Compliance

    LETTER OF COMPLIANCE...
  • Page 52: Ce Certificate

    CE CERTIFICATE...
  • Page 53: Commissioning Check List

    COMMISSIONING CHECK LIST The water heater is not subject to corrosive compounds in the air. □ □ The water supply does not contain chemicals or exceeds total hardness that will damage the heat exchanger. □ Clearances from the water heater unit are met. □...
  • Page 54: Commissioning Sheet

    COMMISSIONING SHEET...
  • Page 55: Service Record

    SERVICE RECORD...
  • Page 56: Maintenance

    The appliance must be inspected, repaired and maintained by a licensed professional. The licensed professional must verify proper operation after servicing. For more detailed instructions on maintenance contact Rinnai or your supplier. Cleaning It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.
  • Page 57: Circulating Pump

    10. Rinse the chemical/water from the water heater as follows: a. Remove the free end of the drain hose (H3) from the pail. Place in sink Rinnai or outside to drain. Water Heater b. Close service valve, (V2), and open shutoff valve, (V4).
  • Page 58 MAINTENANCE Manual draining of the water heater If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the water inside the water heater be drained. To manually drain the water: Cold water Water drain 1 Shut off cold water supply and gas supply.
  • Page 59: Uk Warranty

    UK WARRANTY As the purchaser of this high quality Rinnai Water Heater you are provided with the following condi- tional warranty. Standard (Infinity) Commercial (HD) Labour 1 Year (1 1 Year (1 Parts 3 Years 5 Years Definition of Standard Use.
  • Page 60 WHAT WILL RINNAI DO? Rinnai will repair or replace the product or any part or component that is defective in materials or workmanship, except as set forth below: All repairs must be performed using genuine Rinnai parts. All repairs or replacements must be performed by a registered gas engineer.
  • Page 61: Contact

    CONTACT UK LTD. 9 Christleton Court Manor Park Runcorn Cheshire WA7 1ST Tel. 01928 531870 Fax. 01928 531880 E-mail. info@rinnaiuk.com Web. www.rinnaiuk.com HEATER DETAILS Model Number _____________________________________________ Serial Number _____________________________________________ Date of Purchase _____________________________________________...