Type of appliance
Exhaust system
Rinnai Australia model N"
Installation
Operation
Dimensions
Weight
Connections
Ignition system
Gas consumption
Electrical consumption
Hot water capacity
Temperature range
Water flow control
Minimum operating pressure
Normal operating pressure
Minimum operating water flow
Power supply
Safety devices

SPECIFICATION

Temperature controlled continuous gas hot water system.
Forced combustion.
R E U - 2 4 W - A
Externally mounted.
Remote control, mounted in kitchen and/or bathroom.
Width
-
370 mm.
Height -
538 mm.
210 mm. I With bracket and flue extension ]
-
20 kilograms.
Gas supply
Cold water supply
Hot water supply
Direct electronic ignition.
Natural gas
Normal
Standby
Automatic frost protection
2.2 to 24 L/min . [ Raised 25°C ]
35°C to 75°C in 16 steps.
Electronic water flow control device.
15 kPa.
70 to 830 kPa.
2.5 L/min.
Appliance
Remote control
Flame failure
Remaining flame [OHS]
Boiling protection
Fusible link
Burner light back
Pressure relief valve
Automatic frost protection -
Combustion fan rpm check -
- R W l2OA.
R % l20A.
-
R 3k l20A.
-
185 MI/ h HI, 21 Ml/h LOW.
- 72 Watts.
- 8 Watts.
- 144Watts.
-
2301240 Volts 50 I-Ix.
-
DC 12 Volts Digital.
Flame
rod.
-
200°C bi-metal switch.
-
- 105°C lockout thermistor.
- 152°C thermal fuse.
_
135°C bi-metal switch.
-
-
Closes - 1000 kPa.
Bi-metal sensor & anti-frost heaters.
Integrated circuit system.