Wiring Diagram, 17.5 Kw Manual Transfer Switch - Drawing No. 0G1065 - Generac Power Systems GP Series Diagnostic And Repair Manual

Portable generators
Hide thumbs Also See for GP Series:
Table of Contents

Advertisement

Section 6 Electrical Data
Wiring Diagram, 17.5 kW Manual Transfer Switch – Drawing No. 0G1065
GROUND
(GRN)
NEUTRAL
(WHT)
NEUTRAL
(WHT)
CIRCUIT 9
NEUTRAL
(WHT)
CIRCUIT 11
NEUTRAL
(WHT)
CIRCUIT 13
NEUTRAL
(WHT)
CIRCUIT 15
CIRCUIT 1
(BRN)
CIRCUIT 3
(BRN/WHT)
CIRCUIT 5
(YEL)
CIRCUIT 7
(YEL/WHT)
CIRCUIT 9
(LT BLU)
CIRCUIT 11
(ORG)
CIRCUIT 13
(DRK BLU)
CIRCUIT 15
(PNK)
CIRCUIT 16
(PNK/YEL)
CIRCUIT 14
(BLU/YEL)
CIRCUIT 12
(ORG/YEL)
CIRCUIT 10
(GRY/YEL)
CIRCUIT 8
(VIO/YEL)
CIRCUIT 6
(VIO)
CIRCUIT 4
(ORG/WHT)
CIRCUIT 2
(ORG)
MAIN 2
(RED)
MAIN 1
(BLK)
NEUTRAL
(WHT)
CIRCUIT 16
NEUTRAL
(WHT)
CIRCUIT 14
NEUTRAL
(WHT)
CIRCUIT 12
NEUTRAL
(WHT)
CIRCUIT 10
NEUTRAL
(WHT)
CIRCUIT 8
NEUTRAL
(WHT)
CIRCUIT 6
90
GROUND BAR
GROUND(GRN)*
GEN2(RED)*
GEN1(BLK)*
NEUTRAL(WHT)*
*-CUSTOMER SUPPLIED
NEUTRAL BAR
LOAD CENTER
UTILITY
NEUTRAL BAR
Diagnostic Repair Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultrasource44514986573445824987 ... Show all

Table of Contents