Install front cover to ice machine.
8.1
Install condensing unit
• Complete installation of condensing unit
or connection to rack system.
• Required rack system capacity at 0 F
(–18 C) evaporator (EPR supplied by
installer).
1010N: 7,700 Btu/hr (1940 kcal/hr)
1410N: 10,000 Btu/hr (2519 kcal/hr)
Consult Operation and Service Manual provided with ice machine for sanitizing instructions.
18
Ice machine MUST be sanitized prior to operation!
HARMONY and Symphony Plus • RIDE Technology
remote
8.2
Install ice machine front cover
• Slide ice machine cover over machine
• Insert and tighten two screws through
cover and into docking assembly
NOTICE
8

Front cover