Connect Power
NOTE: The sprayer is rated 200-240 Vac, 1 Phase, 20A,
50/60 Hz. A dedicated 20A circuit with a NEMA L6-20R
receptacle is required.
1. Before use, verify that you have the required
20-Amp circuit with a NEMA L6-20R receptacle.
2. Plug the power cord (Z) into the receptacle.
3A7939A
Extension Cords
If an extension cord is necessary, use a 12 AWG (2.5
2
mm
) or thicker cord to carry the current that the sprayer
draws. Undersized extension cords result in a drop in
line voltage and loss of power and overheating.
Select the minimum cord wire gauge based on length
according to the table below:
Length
50 ft (15.24 m)
100 ft (30.48 m)
200 ft (60.96 m)
300 ft (91.44 m)
Make sure your extension cord is not damaged.
Install Vented Oil Cap Before
Using Equipment
The sprayer's motor gear box is shipped from the
factory pre-filled with oil. The temporary unvented cap
(PX) prevents oil leaks during shipment.
Replace the temporary unvented cap (PX) with the oil fill
cap (P) before use.
P
ti36317a
Installation
Gauge
2
mm
12 AWG
3.31
10 AWG
5.26
6 AWG
13.29
4 AWG
21.14
PX
9