Replace the Rupture Disc
Assembly
1. Follow the Pressure Relief Procedure on page 15
and unplug the power cord (Z)
.
3A7939A
2. Remove elbow (44) from rupture disc assembly
(15).
3. Remove rupture disc assembly (15) from fitting (17).
4. Install new rupture disc assembly into fitting (17).
Use compatible liquid thread sealant or PTFE tape
on connection.
5. Reinstall elbow (44) and position as shown in the
image.