Read the manual carefully before installation and use.
 These devices must be installed by qualified personnel, in compliance with current plant-engineering regulations, in order to avoid damage to persons or property.
 Before any maintenance operation on the device, switch off power supply from measuring and supply inputs.
 The manufacturer assumes no responsibility for electrical safety in the event of improper use of the device.
 The products described in this document are subject to updates or modifications at any time. Data and descriptions in the catalogue therefore do not have any contractual value.
 The building's electrical system must incorporate a switch or circuit breaker. It must be installed close to the equipment and within easy reach of the operator. It must be marked as the disconnecting
device of the equipment: IEC/ EN 61010-1 § 6.12.2.1.
 Clean the instrument with a soft cloth. Do not use abrasives, liquid detergents or solvents.
Contents
Doc: I456GB06_16.docx
ADXL...
SOFT STARTER
INSTRUCTION MANUAL
Page
10
10
13
13
14
14
14
15
15
15
16
16
16
16
17
18
18
19
19
19
20
29/06/2016
2
2
2
2
3
4
4
4
5
5
6
6
6
7
7
7
7
7
8
9
9
9
9
p. 1 / 20

Advertisement

Table of Contents
loading

Summary of Contents for Lovato ADXL Series

  • Page 1: Table Of Contents

    ADXL… SOFT STARTER INSTRUCTION MANUAL Read the manual carefully before installation and use.   These devices must be installed by qualified personnel, in compliance with current plant-engineering regulations, in order to avoid damage to persons or property.  Before any maintenance operation on the device, switch off power supply from measuring and supply inputs. ...
  • Page 2: Description

    Description  Backlit icon LCD.  3 status LEDs (power, ramp/run, fault).  Texts for measurements, settings and messages in 6 languages (ENG-ITA-FRA-ESP-POR-DEU).  Front-mounted keypad with 4 keys, for full parameter setting.  AUTOSET wizard for quick configuration in 4 steps of typical applications (pumps, fire fighting pumps, belt conveyors, mixers, fan, general purpose). ...
  • Page 3: Autoset Guided Configuration

    AUTOSET guided configuration  When a factory-new soft starter is first powered up, the AUTOSET configuration wizard launches, to simplify and speed up the configuration and commissioning of the device.  This procedure consists in prompting the user for 4 simple items of information, which enable the ADXL to configure itself with the values most probably suited to the installation in question.
  • Page 4: Navigating The Display Pages

    Navigating the display pages  The ▲ and ▼ buttons allow the measurement display pages to be scrolled one at a time. The current page is shown in text.  Some of the values may not display, depending on how the starter has been programmed. VALUE DISPLAY Instantaneous current (highest of three phases)
  • Page 5: Startup Methods

    Startup methods  ADXL supports two main start/stop methods: Torque ramps (P05.01 = ON) When ADXL is set to work in torque ramp mode, it controls the output voltage with a PID closed-loop control to ensure that the motor delivers a variable torque to the shaft which follows the programmed acceleration and deceleration ramps.
  • Page 6: Protections

    Protections  The ADXL is equipped with a set of integrated protections to safeguard both the starter and the motor.  Some of these are configurable. Their settings are to found in the P04 Protections menu.  The following table summarises the available protections, and their parameters/alarms: PROTECTION MOTOR / STARTER PARAMETERS...
  • Page 7: Main Menu

    Main menu  To access the main menu, press the ▲and ▼buttons together when the motor is stopped.  This provides you access to the following functions: FUNCTION CODE DISPLAY Set password (if enabled – see P03 ) PASSWORD Launch SETUP menu SETUP Enter EVENTS log list EVENTS...
  • Page 8: User Alarms (Uax)

    Remote variables (REMx)  The ADXL can manage up to 8 variables controlled remotely (REM1…REM8).  The status of these variables can be edited as required by the user by means of the communication protocol and may be used in combination with outputs. ...
  • Page 9: Ir Programming Port

    Parameter setting from smartphone or tablet with CX02 Wi-Fi dongle  You can use the Lovato Electric SAM1 App, available for tablet and smartphone (Android or iOS) and the CX02 Wi-Fi adapter to connect to the ADXL... via its front optical port.
  • Page 10: Parameter Settings (Setup) From Front Panel

    Setting parameters (set-up) from the front panel  The available sub-menus are shown in the following table: Code MENU DESCRIPTION GENERAL Main motor characteristic data UTILITY Language, brightness, display, etc. PASSWORD Access code setup PROTECTIONS Motor/starter protection equipment MISCELLANEOUS Accessory functions INPUTS Programmable digital inputs OUTPUTS...
  • Page 11 P03.01 - If set to OFF, password management is deactivated; access to settings and the control menu is free. P03.02 - With P03.01 active, value to be specified to activate user level access. See the Password protected access chapter. P03.03 - As P03.02, referred to Advanced level access. P03.04 - If set to a numeric value, it becomes the code to be specified via serial communication line before being able to send remote controls.
  • Page 12 P05.01 – Determines whether the acceleration and deceleration ramps are to run under torque or voltage control. P05.02 – Due to the various construction standards (IE2, IE3, etc.), motors may have a different torque delivery than envisaged. In such cases, it is useful to be able to modify the parameter to optimise delivery.
  • Page 13: Alarms

    P09.n.07 Kickstart at start OFF / 50…100 P09.n.08 Motor nominal cosΦ 0.80 0.50…1.00 Note: This menu is divided into 3 sections for each additional motor MOT1..3. The motors are selected via the digital inputs configured with the multiple motor function. P09.n.01 –...
  • Page 14: Table Of Alarms

    COOLING FAN FAULT Fan current too high, rotor probably jammed. COOLING FAN LOCKED Internal error. Please contact Lovato Electric customer service. SYSTEM ERROR UA1..4 USER ALARM The user alarm was generated by the activation of the variable or of the associated input by means of menu P13.
  • Page 15: Programmable Input Defaults Settings

    Disabled input. START Motor start (obligatory: at least one programmable input must be mapped to this function). When closed, it enables starting. It can be used both as a three-wire pulse command or two-wire continuous command (see connection diagrams). STOP Motor stop.
  • Page 16: Commands Menu

    Commands menu  The commands menu is used to perform occasional operations, like resetting measurements, counters, alarms, etc.  If the advanced access password was entered, the commands menu can also be used to perform automatic operations useful for configuring the instrument. ...
  • Page 17: Connection Diagrams

    Connection diagrams Switch disconnector + ultra-rapid fuses MCCB *1 – Optional cooling fan (code EXP8004) *2 – Optional RS485 communications interface (code EXC1042) 2-wire starting Motor PTC connection Starting with reversible rotation OUT2 OUT1 OUT2 OUT3 PROG. OUT. RS485 PROG. IN. * –...
  • Page 18: Mechanical Dimensions

    Mechanical dimensions ADXL0030 - ADXL0045 - ADXL0060 ADXL0075 - ADXL0085 - ADXL0115 Terminal layout A1 A2 11 14 12 21 24 34 C IN1 IN2 IN3 Doc: I456GB06_16.docx 29/06/2016 p. 18 / 20...
  • Page 19: Choosing The Soft Starter

    Choosing the soft starter Code Starter rated Rated duty power IEC FLA [A] Rated duty power UL current Ie [A] Motor power [kW] Motor power [Hp] @230 @400 @500 @208 @220- @380- @440- @550- 240 VAC 415 VAC 480 VAC 600 VAC ADXL 0030 600 18.5...
  • Page 20: Manual Review History

    Manual review history Date Notes 29/06/2016  First release AXIS & Stuifmeel BV Coenecoop 1 2741 PG Waddinxveen Netherlands Tel: +31 (0) 182 64 70 70 www.axis-stuifmeel.nl info@axis-stuifmeel.nl Doc: I456GB06_16.docx 29/06/2016 p. 20 / 20 Official Lovato distributor for the Benelux...