Sony NSS-V2 Installation Manual

Multi-format media server
Hide thumbs Also See for NSS-V2:

Advertisement

Quick Links

MULTI-FORMAT MEDIA SERVER
NSS-V2
DIGITAL INPUT PROCESSOR BOARD
BKNS-V202
DIGITAL OUTPUT PROCESSOR BOARD
BKNS-V203
9PIN CONTROL INTERFACE BOARD
BKNS-V209
INSTALLATION MANUAL
1st Edition (Revised 1)

Advertisement

Table of Contents
loading

Summary of Contents for Sony NSS-V2

  • Page 1 MULTI-FORMAT MEDIA SERVER NSS-V2 DIGITAL INPUT PROCESSOR BOARD BKNS-V202 DIGITAL OUTPUT PROCESSOR BOARD BKNS-V203 9PIN CONTROL INTERFACE BOARD BKNS-V209 INSTALLATION MANUAL 1st Edition (Revised 1)
  • Page 2 Beim Einbau des Geräts ist daher im Festkabel ein leicht zugänglicher Unterbrecher einzufügen, oder das Netzkabel mu ß mit einer in der Nähe des Geräts befindlichen, leicht zugänglichen Wandsteckdose NSS-V2 Serial No.10001 and Higher verbunden werden, damit sich bei einer BKNS-V202 Serial No.10001 and Higher...
  • Page 3 6. When performing the installation, keep the The use of optical instruments with this product following space away from walls in order to will increase eye hazard. obtain proper exhaust and radiation of heat. Rear: 10 cm (4 inches) or more 1 (P) NSS-V2...
  • Page 4 Carrying the unit with less than two persons may cause injury. Mount with more than two persons The total weight of this unit is 21 kg. Mounting the unit with less than two persons may cause injury. 2 (P) NSS-V2...
  • Page 5: Table Of Contents

    IF-972 Board (BKNS-V209) ......2-8 (E) 2-3. Operating Setup Tool ..........2-9 (E) 2-3-1. Setup Tool Descriptions ....... 2-10 (E) 2-3-2. Changing Setup Table ........2-11 (E) 2-3-3. Changing the Setup Values using Dynamic Setup ..........2-12 (E) 1 (E) NSS-V2...
  • Page 7: Manual Structure

    Related manuals Besides this Installation Manual, the following manuals are available for the NSS-V2..NSS-V2 Operation Manual (supplied with the NSS-V2) This manual describes the application and operation of the NSS-V2. Part number: 3-903-845-XX ..NSS-V2 Maintenance Manual (available on request)
  • Page 9: Installation

    Red Hat Linux ES, TimeSys Linux CPU: Intel Xem 3.4 GHz or more Memory: 2 GB or more HDD: 36 GB or more Ethernet: 100Base-TX For the newest information on the personal computer, please contact your local Sony Sales Office/ Service Center. 1-1 (E) NSS-V2...
  • Page 10: Operating Conditions And Installation Space

    BKNS-V203 : Approx. 1 kg (per one set) BKNS-V209 : Approx. 1 kg (per one set) To prevent overheating of the NSS-V2 ensure that there is good air circulation around the unit. Do not install the unit in humid or dusty environment.
  • Page 11 Do not stop the fan or block the ventilatior because this unit is air-cooled by the fan of the power supply. If not, a fire or failure may occur. (440) 113.3 115.5 MULTI-FORMAT MEDIA SERVER NSS-V2 POWER SYSTEM 390.4 72.8...
  • Page 12: Power Supply

    3-613-640-01 AC inlet If the unit is used in the area except above, please contact your local Sony Sales Office/Service Center. . Use the specified power cord only. . Do not damage to the power cord. . Ground the unit safely.
  • Page 13: Rack Mounting

    . Adaptor fixing screws (B4 x 10: 7-682-562-09) : 6 pcs Required other parts To mount the unit in the rack, the following parts are required. (supplied with the NSS-V2) . Screw (RK5 x 16: 7-682-378-04) : 4 pcs . Ornamental washers (2-297-913-01)
  • Page 14 Rack angle Ornamental washers 31.75 B4 x 10 RK5 x 16 Ornamental B4 x 10 31.75 washers RK5 x 16 Unit : mm Rack angle 6. Fasten the length adjustment screws which are loos- ened in step 4. 1-6 (E) NSS-V2...
  • Page 15: Installing The Option Boards

    . Do not leave the rear slot open in order to maintain the Blank panel cooling effect in the NSS-V2. Be sure to install the blank panel to an open slot. . The BKNS-V202/V203 can be used in slots 1 to 4, 7 and 3.
  • Page 16: Installing The Bkns-V209

    . Do not leave the rear slot open in order to maintain the 3. Insert the IF-972 board of the BKNS-V209 into slot 9 cooling effect in the NSS-V2. Be sure to install the blank or 10, and securely connect it to the motherboard by panel to an open slot.
  • Page 17: Signal Input And Output

    Pin No. Signal FRAME GND TX _ <External view> RX + Pin No. Signal TX + TX _ TX + RX + RX _ FRAME GND RX _ FIBRE CHANNEL : LC connector <External View> Pin No. Signal 1-9 (E) NSS-V2...
  • Page 18: Connecting Connectors And Cables

    When connecting cables to various connectors on the rear panel at the time of installing or servicing, connect the following connectors/cable or their equivalents. NSS-V2 Matching Connector/Cable Panel Indication Connector Connector/Cable Sony Part No. TC IN 1-569-370-12 Belden 8281 cable SDI IN BNC 75 Z BNC 75 Z...
  • Page 19: Connection

    1-8. Connection The connection of the 12 I/O configuration is as follows. Connect two units of NSS-V2 and two units of NSS-S2 via the fiber channel. Connect the LOCAL Ethernet and the GLOBAL Ethernet as shown in the following figure.
  • Page 20: Setting After Installation

    When using multiple number of NSS-V2 units, perform setting of the ID switch on the SY-318 board (chassis number setting). Set the chassis number in order from 1 to the number of NSS-V2 units to be used without duplication. Setting example: .
  • Page 21: Service Overview

    Cleaning A filter is fitted on the rear side of the front panel of the 1. Turn off the main power of the NSS-V2. unit. If accumulated dust on the filter impedes the flow of 2. Fully loosen the two screws (with drop-safe) and air, the inside may heat up and troubles may occur.
  • Page 22: Functional Descriptions Of Board Switches

    Lights on when FC3 when the link of FC3 is connected. is used. D1003 (Side B A-4) Green FC4 LINK Lights while receiving/transmitting the data Lights on when FC4 when the link of FC4 is connected. is used. 2-2 (E) NSS-V2...
  • Page 23 S102 (H-1) Factory Use S501 (H-4) Factory Use All OFF 1 2 3 4 5 6 7 8 S711 (A-4) ID SW Sets the shassis number of NSS-V2. LEDs Ref. No. Address Indication Name Function Normal state color D101 (H-1)
  • Page 24 Normal state color D110 (F-1) Factory Use D201 (D-1) Green CONF DONE Lights when the FPGA cofiguration is Lights on complete. D401 to D408 (F-3) Factory Use D409 (G-3) D503 (C-1) D603 to D607 (G-1) ND501 (G-3) 2-4 (E) NSS-V2...
  • Page 25 (B-5) Factory Use S701 (G-2) Factory Use All OFF 1 2 3 4 5 6 7 8 LEDs Ref. No. Address Indication Name Function Normal state color D701 to 708 (G-1) Factory Use D601 to 604 (C-1) 2-5 (E) NSS-V2...
  • Page 26 (J-2) D501 (K-4) D502 (K-4) D503 (A-2) Amber Lights when the board can be removed while Lights off the NSS-V2 is being powered. D505 (B-2) Factory Use D510 to D517 (K-4) D801 to D804 (C-4) D805 to D808 (D-4) D809...
  • Page 27: Board (Bkns-V203)

    D409 (H-2) D501 (K-4) D502 (K-4) D503 (A-2) Amber Lights when the board can be removed while Lights off the NSS-V2 is being powered. D505 (B-2) Factory Use D510 to D517 (K-4) D1101 to D1104 (E-4) D1109 (E-4) D1401 (F-1)
  • Page 28: Board (Bkns-V209)

    2-2-7. IF-972 Board (BKNS-V209) D101 (Side A/component side) LEDs Ref. No. Address Indication Name Function Normal state color D101 (H-1) Factory Use 2-8 (E) NSS-V2...
  • Page 29: Operating Setup Tool

    1. Connect the PC to the global network of the system with the Ethernet cable. Preparation 1. Copy the file of above-mentioned “Table of required files” onto an arbitrary folder of PC (desktop etc.). 2. Double-click the SetupTool.exe copied onto an arbitrary folder, and start up the Setup Table Update application. 2-9 (E) NSS-V2...
  • Page 30: Setup Tool Descriptions

    Dynamic Setup is displayed as active only when the applicable items are clicked. When FM is not running, an error occurs for the connec- tion requirement from Tool, and the Connection Error message appears. 4. Exit button Closes Tool. 2-10 (E) NSS-V2...
  • Page 31: Changing Setup Table

    Password: Password of FM 2 Local Settings Local folder where the Setup Table file is saved 4) The changed items are displayed in red. Confirm the Help changes and click the “Update” button. 1. Version Displays the Version screen. 2-11 (E) NSS-V2...
  • Page 32: Changing The Setup Values Using Dynamic Setup

    Setup Table can be immediately notified to IOBox. The “Dynamic Setup” button is unavailable for some items. For such items, the “Dynamic Setup” button is disabled. 1) After the setup values are changed, click the “Dynamic Setup” button with the changed item being selected. 2-12 (E) NSS-V2...
  • Page 33 Specifies the number of the constituting NSS-S2 units. HDD Size Specifies the HDD size of the NSS-S2. 250 GB Number of I/O Box Specifies the number of the constituting NSS-V2 units. Time Slot Cycle Specifies the time slot cycle. 3000 ms 5000 ms Number of Net I/F Specifies the number of the constituting BZN-202 units.
  • Page 34 2-14 (E) NSS-V2...
  • Page 35 2-15 (E) NSS-V2...
  • Page 36 2-16 (E) NSS-V2...
  • Page 37 2-17 (E) NSS-V2...
  • Page 38: Building File Manager-Pc

    . Be careful to enter the network settings since they are all cleared when reentering them. The logical IF typically corresponds to the physical IF as follows. If the network card is not added Logical IF Physical IF eth0 On board NIC1 eth1 On board NIC2 2-18 (E) NSS-V2...
  • Page 39: Installation

    . When attempting to stop File Manager during backup, the following message appears. File Manager cannot be stopped unless backing up is completed. [root@FM log]# /usr/local/edgestore/run-FM.sh \ stop " Now Backuping. After a minute, Please retry run-FM.sh stop. 2-19 (E) NSS-V2...
  • Page 40 Execute the following diagnostic command to check if all the displayed results are OK. /usr/local/edgestore/bin/fmdiag.sh If no problem exists, following output is displayed. [root@FM root]# /usr/local/edgestore/bin/fmdiag.sh " IP Setting [ OK ] Directory Setting [ OK ] Setting File [ OK ] Run Level [ OK ] 2-20 (E) NSS-V2...
  • Page 41 1950 1798 0 15:48 pts/0 00:00:00 grep File Manager (↑ The remaining File Manager process number is confirmed.) # kill \ -9 \ 1922 \ 1930 \ 1950 " (Where the underlined part is the process number.) 2-21 (E) NSS-V2...
  • Page 42: Installing Transfer Manager

    HP, and Transfer Manager. During installation, the PC is restarted twice, which are performed automatically. The installation itself is completed at the second restart. After the second restart of the PC, Transfer Manager automatically starts. 2-22 (E) NSS-V2...
  • Page 43 /root netif netif /mnt/egfs User for connecting to the FTP mediavenue mediavenue /usr/local/netif/update User for updating NetIF FTP reboot No Password /usr/local/netif User for restarting the OS shutdown No Password /sbin User for stopping the OS 2-23 (E) NSS-V2...
  • Page 44 Type your Global IP Address (CurrentSetting : 192.168.1.10) 192.168.1.12 3 Setting the Global Ethernet NetMask Set the NetMask for the Global Ethernet. The default value is typically used without any problem. Example: Type your Global NetMask (currentSetting : 255.255.255.0) (None) 2-24 (E) NSS-V2...
  • Page 45 Global NetMask: 255.255.255.0 Global gateway: Global Nameserver: Host Name: TM-MediaVenue1 OK? [y/n] In the above example, default values are used for the gateway address and the name server address, so that nothings are set for these items. 2-25 (E) NSS-V2...
  • Page 46 If you press y key, the screen changes to the one shown in the Figure 2 and formatting of the local disk is started. Figure 2. Formatting the local disk (3) When formatting is completed, installation of packages comprising the operating system starts. Figure 3. Installation of various packages 2-26 (E) NSS-V2...
  • Page 47 Installation of the drivers made by HP and Transfer Manager is automatically performed at the first restart of the system. The screen shown in the Figure 5 remains displayed for about 30 minutes during installation. If the screen disappears in the course of installation, press the Shift key to reappear it. 2-27 (E) NSS-V2...
  • Page 48 Fibre Channel cable, and set all the environments including FM and I/O Box, then restart Transfer Manager-PC. After restarting the PC, messages appear as shown in Figure 7. Figure 7. Startup screen when the system is running If the message “Started” appears on the screen, Transfer Manager is running successfully. 2-28 (E) NSS-V2...
  • Page 49: Startup/Stop

    If you enter [http:// the IP address of the Transfer Manager Global Network], the top screen as shown in Figure 8 appears. By clicking the “Service Setting” link on the screen, a screen as shown in Figure 9 appears. Figure 9. Service Setting (stopped) screen 2-29 (E) NSS-V2...
  • Page 50 The OS can also be restarted or stopped simply by logging in as the “shutdown” or “reboot” user (no password required), as well as logging in as the root user and executing the shutdown or reboot command as described above. 2-30 (E) NSS-V2...
  • Page 51: Setting Mcdata Fc Switch

    C> ipconfig " ← Confirmation of the changed settings MAC Address : 08 00 88 60 4a fc IP Address : 192.168.0.201 Subnet Mask : 255.0.0.0 Gateway Address : 0.0.0.0 C> 5. Close the terminal software, and disconnect the serial cable. 2-31 (E) NSS-V2...
  • Page 52 Set 1 back to the original value. 5 Configure - Ports - Type - Gx Port → Fx Port Configure all ports that you use. 6 Configure - Ports - Type - Speed → Negotiate (Default) Configure all ports that you use. 2-32 (E) NSS-V2...
  • Page 53 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.
  • Page 54 NSS-V2 (SY) BKNS-V202 (SY) BKNS-V203 (SY) Printed in Japan Sony Corporation BKNS-V209 (SY) J, E 2006. 8 16 3-903-856-02 ©2005...

Table of Contents